New method for in live-line detection of small defects in composite insulator based on electro-optic E-field sensor
Authors:
- 11 February 2013
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 20 (1) , 194-201
Abstract
Preliminary results based on experimental tests in laboratory and numerical investigation concerning the live-line detection of a conductive defect in HV composite insulator are depicted. The proposed method is based on E-field sensing using a non-invasive and compact pigtailed electro-optic (EO) single-ended probe. Measurements and numerical FEM modeling were done on a clean dead-end 28 kV composite insulator on which conductive defects of different size and position were simulated. Based on these simulations, the optimal location and orientation of the EO probe were determined regarding the conductive defect length and position. Laboratory tests were performed to validate these results and demonstrate the efficiency of the new detection method. The experimental results have demonstrated that using the optimal EO probe orientation, the E-field sensor was able to detect and locate conductive defect as short as 15 mm × 1 mm in contact with the HV electrode and of 26 mm × 2 mm between sheds. Moreover, the experimental tests have demonstrated the ability of the EO sensor to detect the presence of corona discharges induced by the conductive defects.Keywords
This publication has 9 references indexed in Scilit:
- Two electric-field components measurement using a 2-port pigtailed electro-optic sensorApplied Physics Letters, 2011
- Fully Automated E-Field Measurement System Using Pigtailed Electro-Optic Sensors for Temperature-Dependent-Free Measurements of Microwave Signals in Outdoors ConditionsIEEE Sensors Journal, 2008
- Electric field and temperature measurement using ultra wide bandwidth pigtailed electro-optic probesApplied Optics, 2008
- Diagnostic Methods for Outdoor Polymeric InsulatorsIEEE Transactions on Dielectrics and Electrical Insulation, 2007
- Quantification of corona discharges on nonceramic insulatorsIEEE Transactions on Dielectrics and Electrical Insulation, 2005
- Effect of long-term corona on non-ceramic outdoor insulator housing materialsIEEE Transactions on Dielectrics and Electrical Insulation, 2001
- Experience with the detection of faulty composite insulators on high-voltage power lines by the electric field measurement methodIEEE Transactions on Power Delivery, 1998
- Electrical test methods for nonceramic insulators used for live line replacementIEEE Transactions on Power Delivery, 1997
- New live line tester for porcelain suspension insulators on high-voltage power linesIEEE Transactions on Power Delivery, 1994