Relative Threshold of Detection of Active Arterial Bleeding: In Vitro Comparison of MDCT and Digital Subtraction Angiography

Authors:

Abstract
OBJECTIVE. The objective of our study was to determine the relative sensitivity and the lowest threshold of bleeding detectable with digital subtraction angiography (DSA) and with MDCT using an in vitro physiologic system.MATERIALS AND METHODS. A closed pulsatile cardiopulmonary bypass circuit was connected to tubes traversing a water bath to simulate the abdominal aorta and inferior vena cava. Three smaller interconnecting acrylic plastic tubes were connected as branches to the aortic tubing to simulate branch vessels. One of the three tubes, the control, had no holes in it, one had a 100-μm hole, and one had a 280-μm hole. The leakage rates were predetermined with a cardiac output of 2 and 4 L/min and with a mean arterial pressure (MAP) ranging from 30 to 100 mm Hg for each hole size. The following studies were performed for each of the predetermined leakage rates. For study 1, 16-MDCT was performed using bolus tracking after 35 mL of contrast medium had been injected into a simulated peripheral vein. F...

This publication has 27 references indexed in Scilit: