Abstract
Magnetic‐equivalent‐circuit model for surface mounted permanent‐magnet synchronous machines inboth healthy and faulty cases is presented in this study, where both saturationeffect and space harmonics are considered. Pole numbers, magnets and slotnumbers can be chosen arbitrarily in the proposed model, and the behavior of themachine can be studied under various kinds of faults by a single model. Demagnetization, as well as inter‐turn short short‐circuit faults of the statorwindings, are modelled, and a fault detection method is proposed. It is shownthat the demagnetization fault is not detectible by stator current analysis,therefore an additional pole specific coil is considered in this study as asearch coil. For modelling, the differential equations representing theelectrical part of the PMSM model are converted into an algebraic type using thewell‐known trapezoidal technique and are solved simultaneously together with thenon‐linear magnetic equations using the Newton‐Raphson method. It is shown thatthe presented model in this study is capable of effective modelling of thehealthy and faulty machine under mentioned faults by a single model, thusreducing the computational complexity of the model. The effectiveness of theproposed MEC model is verified using finite‐element method via Maxwellsoftware.

This publication has 33 references indexed in Scilit: