Characterization of cell lysis events on a microfluidic device for high‐throughput single cell analysis
- 25 October 2011
- journal article
- microfluidics and-miniaturization
- Published by Wiley in Electrophoresis
- Vol. 32 (22) , 3172-3179
Abstract
A microfluidic device capable of rapidly analyzing cells in a high‐throughput manner using electrical cell lysis is further characterized. In the experiments performed, cell lysis events were studied using an electron multiplying charge coupled device camera with high frame rate (>100 fps) data collection. It was found that, with this microfluidic design, the path that a cell follows through the electric field affects the amount of lysate injected into the analysis channel. Elimination of variable flow paths through the electric field was achieved by coating the analysis channel with a polyamine compound to reverse the electroosmotic flow (EOF). EOF reversal forced the cells to take the same path through the electric field. The improved control of the cell trajectory will reduce device‐imposed bias on the analysis and maximizes the amount of lysate injected into the analysis channel for each cell, resulting in improved analyte detection capabilities.Keywords
This publication has 28 references indexed in Scilit:
- Recent advances in single-cell analysis using capillary electrophoresis and microfluidic devicesJournal of Chromatography B, 2008
- Analysis of single mammalian cells on-chipLab on a Chip, 2007
- Transcending the biomarker mindset: deciphering disease mechanisms at the single cell levelCurrent Opinion in Chemical Biology, 2006
- Microfluidics-based systems biologyMolecular BioSystems, 2006
- Microfabricated System for Parallel Single-Cell Capillary ElectrophoresisAnalytical Chemistry, 2004
- A polyamine coating for enhanced capillary electrophoresis‐electrospray ionization‐mass spectrometry of proteins and peptidesElectrophoresis, 2004
- Integration of single cell injection, cell lysis, separation and detection of intracellular constituents on a microfluidic chipElectronic supplementary information (ESI) available: Video showing a single erythrocyte transported through the microchannel, docking (adhering) at a particular point and then being lysed. See http://www.rsc.org/suppdata/lc/b3/b310552k/Lab on a Chip, 2003
- Microfluidic Devices for the High-Throughput Chemical Analysis of CellsAnalytical Chemistry, 2003
- New approaches to single-cell analysis by capillary electrophoresisTrAC Trends in Analytical Chemistry, 2001
- Laser−Micropipet Combination for Single-Cell AnalysisAnalytical Chemistry, 1998