Optimization of temporal sampling for 18F-choline uptake quantification in prostate cancer assessment
Authors:
- Xavier Palard-NovelloXPXavier Palard-Novello
- Anne-Lise BlinABAnne-Lise Blin
- Florence Le JeuneFJFlorence Le Jeune
- Etienne GarinEGEtienne Garin
- Pierre-Yves SalaünPSPierre-Yves Salaün
- Anne DevillersADAnne Devillers
- Giulio GambarotaGGGiulio Gambarota
- Solène QuerellouSQSolène Querellou
- Patrick BourguetPBPatrick Bourguet
- Hervé Saint-JalmesHSHervé Saint-Jalmes
Open Access
- 15 June 2018
- journal article
- research article
- Published by Springer Nature in EJNMMI Research
- Vol. 8 (1) , 49
Abstract
Suboptimal temporal sampling of time-activity curves (TAC) from dynamic 18F-fluoromethylcholine (FCH) PET images may introduce bias in quantification of FCH uptake in prostate cancer assessment. We sought to define an optimal temporal sampling protocol for dynamic FCH PET imaging. Seven different time samplings were tested: 5 × 60″, 10 × 30″, 15 × 15″–1 × 75″, 6 × 10″–8 × 30″, 12 × 5″–8 × 30″; 10 × 5″–4 × 10″–3 × 20″–5 × 30″, and 8 × 3″–8 × 12″–6 × 30″. First, the irreversible and reversible one-tissue compartment model with blood volume parameter (VB) (respectively, 1T1K+VB and 1T2k+VB, with K1 = transfer coefficient from the arterial blood to the tissue compartment and k2 = transfer coefficient from the tissue compartment to the arterial blood) were compared for 37 lesions from 32 patients who underwent FCH PET imaging for initial or recurrence assessment of prostate cancer, and the model was selected using the Akaike information criterion. To determine the optimal time sampling, K1 values extracted from 1000 noisy-simulated TAC using Monte Carlo method from the seven different time samplings were compared to a target K1 value which is the average of the K1 values extracted from the 37 lesions using an imaging-derived input function for each patient. K1 values extracted with the optimal time sampling for each tumoral lesion were compared to K1 values extracted from each of the other time samplings for the 37 lesions. The 1T2k + VB model was selected. The target K1 value as the objective was 0.506 mL/ccm/min (range 0.216–1.246). Results showed a significant difference between K1 values from the simulated TAC with the seven different time samplings analyzed. The closest K1 value from the simulated TAC to the target K1 value was obtained by the 12 × 5″–8 × 30″ time sampling. Concerning the clinical validation, K1 values extracted from the optimal time sampling (12 × 5″–8 × 30″) were significantly different with K1 values extracted from the other time samplings, except for the comparison with K1 values extracted from the 10 × 5″–4 × 10″–3 × 20″–5 × 30″ time sampling. A two-phase framing of dynamic PET reconstruction with frame durations of 5 s (blood phase) and 30 s (tissue phase) could be used to sample the TAC for uptake quantification in prostate cancer assessment.Keywords
This publication has 32 references indexed in Scilit:
- 11C-Choline PET/CT Predicts Prostate Cancer–Specific Survival in Patients with Biochemical Failure During Androgen-Deprivation TherapyJournal of Nuclear Medicine, 2014
- Impact of 18F-Choline PET/CT in Prostate Cancer Patients with Biochemical Recurrence: Influence of Androgen Deprivation Therapy and Correlation with PSA KineticsJournal of Nuclear Medicine, 2013
- Dual-Phase PET-CT to Differentiate [18F]Fluoromethylcholine Uptake in Reactive and Malignant Lymph Nodes in Patients with Prostate CancerPLOS ONE, 2012
- Dose-escalation using intensity-modulated radiotherapy for prostate cancer - evaluation of quality of life with and without 18F-choline PET-CT detected simultaneous integrated boostRadiation Oncology, 2012
- Optimising18F-choline PET/CT acquisition protocol in prostate cancer patientsNorth American Journal of Medical Sciences, 2012
- Prostate Cancer: PET with 18F-FDG, 18F- or 11C-Acetate, and 18F- or 11C-CholineJournal of Nuclear Medicine, 2010
- PET Imaging of Prostate Cancer Using Radiolabeled CholinePET Clinics, 2009
- Fluorocholine PET/CT in Patients with Prostate Cancer: Initial ExperienceRadiology, 2005
- Kinetics of [ 11 C]choline uptake in prostate cancer: a PET stydyEuropean Journal of Nuclear Medicine and Molecular Imaging, 2004
- Dynamic PET Data AnalysisJournal of Computer Assisted Tomography, 1986