Stretch and Wrap Style Tourniquet Effectiveness With Minimal Training
Authors:
Open Access
- 1 November 2012
- journal article
- research article
- Published by Oxford University Press (OUP) in Military Medicine
- Vol. 177 (11) , 1366-1373
Abstract
The objective was to determine if proper application of the Stretch, Wrap, and Tuck Tourniquet (SWAT-T) would stop arterial flow and would occur with minimal training. Methods: Fifteen undergraduates watched a 19 second video three times, practiced twice, and applied the tourniquet to volunteers at 10 locations: 3 above the elbow or knee and 2 below. Results: Successful occlusion (60 second Doppler signal elimination) was more frequent than proper stretch (96 versus 75), more frequent on arms than legs (59 versus 37), and achieved before completed application (16 ± 8 versus 33 ± 8 seconds; each p < 0.05). Proper stretch (correct alteration of shapes printed on the tourniquet) was more frequent on legs than arms (30 versus 45; p < 0.05). Applications were rated Easy (101), Challenging (37), Difficult (12) with discomfort None (53), Little (62), Moderate (34), Severe (1). The 8 appliers with p < 0.01). Conclusions: Proper application of the SWAT-T is easy and can stop extremity arterial flow but requires some training for many appliers.Keywords
This publication has 14 references indexed in Scilit:
- Battle Casualty Survival with Emergency Tourniquet Use to Stop Limb BleedingThe Journal of Emergency Medicine, 2011
- Use of Tourniquets and Their Effects on Limb Function in the Modern Combat EnvironmentFoot and Ankle Clinics, 2010
- Tourniquet Application in a Rural Queensland HEMS EnvironmentAir Medical Journal, 2009
- The Return of Tourniquets: Original Research Evaluates the Effectiveness of Prehospital Tourniquets for Civilian Penetrating Extremity InjuriesJems : a Journal of Emergency Medical Services, 2008
- Practical Use of Emergency Tourniquets to Stop Bleeding in Major Limb TraumaJournal of Trauma: Injury, Infection & Critical Care, 2008
- Evaluation of Possible Tourniquet Systems for Use in the Canadian Forces2006
- Mortality from Isolated Civilian Penetrating Extremity Injury2005
- Effectiveness of Self-Applied Tourniquets in Human VolunteersPrehospital Emergency Care, 2005
- Evaluation of Possible Battlefield Tourniquet Systems for the Far-Forward SettingMilitary Medicine, 2000
- Occlusion of Arterial Flow in the Extremities at Subsystolic Pressures Through the Use of Wide Tourniquet CuffsClinical Orthopaedics and Related Research, 1993