Abstract
Setting and Design: The current in vitro study was conducted from September to December 2021 at the Craniofacial laboratory at the Saint Joseph University in Beirut, Lebanon. Materials and Methods: The shades of 2.0 mm thick, 10.0 mm in diameter disk shaped specimens of VITA CAD Temp® and Ceramill® TEMP were measured using the VITA Linearguide 3D MASTER® and a conversion table to extract the CIE L*a*b* values on a white background (n = 30). Statistical Analysis Used: The color differences ΔE at 3, 6, and 12 months were calculated and analyzed by repeated measures ANOVA followed by Bonferroni multiple comparisons, univariate analyses, and one sample t tests. Results: The mean ΔET1/T0, ΔET2/T0, and ΔET3/T0 values were significantly higher than the cutoff values for acceptability and perceptibility for the VITA CAD Temp® and the Ceramill® TEMP groups. In addition, the increase in ΔE overtime was significantly greater in the Ceramill® TEMP group compared to the VITA CAD Temp® group. Conclusions: The Ceramill® TEMP changed color more and faster than the VITA CAD Temp®. In addition, whether at 3, 6, or 12 months, the color variations of both materials are not only perceptible but also unacceptable compared to the initial shade....

This publication has 19 references indexed in Scilit: