Numerical simulation of the gas–liquid two-phase flow in aeration tank based on different multiphase models
Authors:
- Jinnan GuoJGJinnan Guo
- Liang DongLDLiang Dong
- Jiawei LiuJLJiawei Liu
Open Access
- 1 July 2020
- conference paper
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1600 (1)
Abstract
In this paper, the Eulerian model and Mixture model are used to study the free surface, internal flow and mass transfer in the aeration tank. The two multiphase models affect the liquid velocity, internal flow and oxygen mass transfer coefficient (kLa) of the tank. Eulerian model than the Mixture model significantly higher simulates the liquid velocity near the impeller, and the range of the main longitudinal circulation vortex is smaller than Mixture model. The error between the simulated kLa of Eulerian model and the experimental value is smaller than Mixture model. The results show that the Eulerian model is more suitable for the simulation of the gas–liquid two-phase flow in the aeration tank.Keywords
This publication has 3 references indexed in Scilit:
- Experimental Study and Numerical Simulation of Gas–Liquid Two-Phase Flow in Aeration Tank Based on CFD-PBM Coupled ModelWater, 2020
- Study on the internal two-phase flow of the inverted-umbrella aeratorAdvances in Mechanical Engineering, 2019
- CFD-PBM approach with modified drag model for the gas–liquid flow in a bubble columnChemical Engineering Research and Design, 2016