Abstract
The first series of three workers who developed occupational asthma following exposure to airborne chloramines in indoor chlorinated swimming pools is reported. Health problems of swimmers in indoor pools have traditionally been attributed to the chlorine in the water. Chlorine reacts with bodily proteins to form chloramines; the most volatile and prevalent in the air above swimming pools is nitrogen trichloride.Two lifeguards and one swimming teacher with symptoms suggestive of occupational asthma kept 2-hourly measurements of peak expiratory flow at home and at work, analysed using the occupational asthma system (OASYS) plotter, and/or had specific bronchial challenge testing to nitrogen trichloride, or a workplace challenge.Air measurement in one of the pools showed the nitrogen trichloride levels to be 0.1−0.57 mg·m−3, which was similar to other studies. Two workers had peak expiratory flow measurements showing occupational asthma (OASYS-2 scores 2.88 and 3.8), both had a positive specific challenge to nitrogen trichloride at 0.5 mg·m−3with negative challenges to chlorine released from sodium hypochlorite. The third worker had a positive workplace challenge.Swimming-pool asthma due to airborne nitrogen trichloride can occur in workers who do not enter the water because of this chloramine. The air above indoor swimming pools therefore needs to be assessed and managed as carefully as the water.Keywords
This publication has 8 references indexed in Scilit:
- Respiratory symptoms and bronchial responsiveness in lifeguards exposed to nitrogen trichloride in indoor swimming pools.Occupational and Environmental Medicine, 1998
- Development of OASYS-2: a system for the analysis of serial measurement of peak expiratory flow in workers with suspected occupational asthma.Thorax, 1996
- EXPOSURE TO CHLORAMINES IN THE ATMOSPHERE OF INDOOR SWIMMING POOLSAnnals of Occupational Hygiene, 1995
- Determination of trace amounts of chloramines by liquid chromatographic separation and amperometric detectionAnalytica Chimica Acta, 1990
- The fate of chlorine and chloramines in cooling towers Henry's law constants for flashoffWater Research, 1984
- Rapid method for measurement of bronchial responsiveness.Thorax, 1983
- Distribution and balance of volatile halogenated hydrocarbons in the water and air of covered swimming pools using chlorine for water disinfectionWater Research, 1981
- Adverse respiratory health effects of competitive swimming: the prevalence of symptoms, illnesses, and bronchial responsiveness to methacholine and exercise