Breast composition measurement with a cadmium-zinc-telluride based spectral computed tomography system
Authors:
- 17 February 2012
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 39 (3) , 1289-1297
Abstract
Purpose: To investigate the feasibility of breast tissue composition in terms of water, lipid, and protein with a cadmium-zinc-telluride (CZT) based computed tomography(CT) system to help better characterize suspicious lesions. Methods: Simulations and experimental studies were performed using a spectral CT system equipped with a CZT-based photon-counting detector with energy resolution. Simulations of the figure-of-merit (FOM), the signal-to-noise ratio(SNR) of the dual energy image with respect to the square root of mean glandular dose (MGD), were performed to find the optimal configuration of the experimental acquisition parameters. A calibration phantom 3.175 cm in diameter was constructed from polyoxymethylene plastic with cylindrical holes that were filled with water and oil. Similarly, sized samples of pure adipose and pure lean bovine tissues were used for the three-material decomposition. Tissue composition results computed from the images were compared to the chemical analysis data of the tissue samples. Results: The beam energy was selected to be 100 kVp with a splitting energy of 40 keV. The tissue samples were successfully decomposed into water, lipid, and protein contents. The RMS error of the volumetric percentage for the three-material decomposition, as compared to data from the chemical analysis, was estimated to be approximately 5.7%. Conclusions: The results of this study suggest that the CZT-based photon-counting detector may be employed in the CT system to quantify the water, lipid, and protein mass densities in tissue with a relatively good agreement.Keywords
Funding Information
- National Institutes of Health (R01CA13687)
- National Cancer Institute (R01CA13687)
This publication has 52 references indexed in Scilit:
- MicroCT with energy-resolved photon-counting detectorsPhysics in Medicine & Biology, 2011
- Imaging of nanoparticles with dual-energy computed tomographyPhysics in Medicine & Biology, 2011
- The Mammographic Density of a Mass Is a Significant Predictor of Breast CancerRadiology, 2011
- Computed Tomography in Color: NanoK‐Enhanced Spectral CT Molecular ImagingAngewandte Chemie International Edition, 2010
- In vivowater state measurements in breast cancer using broadband diffuse optical spectroscopyPhysics in Medicine & Biology, 2008
- Energy-resolved computed tomography: first experimental resultsPhysics in Medicine & Biology, 2008
- ImageJ, A Useful Tool for Biological Image Processing and AnalysisMicroscopy and Microanalysis, 2007
- WE-E-L100J-07: Breast CT with Energy Resolved DetectionMedical Physics, 2007
- Mammographic Density and the Risk and Detection of Breast CancerNew England Journal of Medicine, 2007
- Diffusion-weighted magnetic resonance imaging and its application to cancerCancer Imaging, 2006