Changes in finger-aorta pressure transfer function during and after exercise
Authors:
- 1 October 2006
- journal article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 101 (4) , 1207-1214
Abstract
Noninvasive finger blood pressure has become a surrogate for central blood pressure under widely varying circumstances. We tested the validity of finger-aorta transfer functions (TF) to reconstruct aortic pressure in seven cardiac patients before, during, and after incremental bicycle exercise. The autoregressive exogenous model method was used for calculating finger-aorta TFs. Finger pressure was measured noninvasively using Finapres and aortic pressure using a catheter-tip manometer. When applying the individual TFs found during rest for reconstruction of aortic pressure during all workloads, systolic pressure was increasingly underestimated, with large variation between subjects: +4.0 to −18.1 mmHg. In most subjects, diastolic pressure was overestimated: −3.9 to +5.5 mmHg. Pulse pressure estimation varied between +4.5 and −21.9 mmHg. In all cases, wave distortion was present. Postexercise, error in reconstructed aortic systolic pressure slowly declined, and diastolic pressure was overestimated. During rest, the TF gain had a minimum between 3.65 and 4.85 Hz (Fmin). During exercise, Fmin shifted to frequencies between 4.95 and 7.15 Hz at the maximum workload, with no change in gain. Postexercise, gain in most subjects shifted to values closer to unity, whereas Fmin did not return to resting values. Within each subject, aorta-Finapres travel time was linearly related to mean pressure. During exercise, Fmin was linearly related to both delay and heart rate. We conclude that, during increasing exercise, rest TFs give an increasingly unreliable reconstruction of aortic pressure, especially at higher heart rates.Keywords
This publication has 36 references indexed in Scilit:
- Effect of non-invasive calibration of radial waveforms on error in transfer-function-derived central aortic waveform characteristicsClinical Science, 2004
- Estimation of central aortic pressure by SphygmoCor® requires accurate peripheral pressure measurementClinical Science, 2004
- Effects of Heart Rate Changes on Arterial Distensibility in HumansHypertension, 2003
- Pressure Wave Reflection Assessed From the Peripheral PulseHypertension, 2003
- Heart RateHypertension, 2002
- Prospective Evaluation of a Method for Estimating Ascending Aortic Pressure From the Radial Artery Pressure WaveformHypertension, 2001
- Where is the evidence that radial artery tonometry can be used with a generalised transfer function to accurately and non-invasively predict central aortic blood pressure?Journal of Human Hypertension, 2001
- Evaluation of non-invasive blood pressure measurement by the Finapres method at rest and during dynamic exercise in subjects with cardiovascular insufficiencyClinical Autonomic Research, 1994
- The difference in blood pressure between upper arm and finger during physical exerciseClinical Physiology and Functional Imaging, 1988
- Disparities Between Aortic and Peripheral Pulse Pressures Induced by Upright Exercise and Vasomotor Changes in ManCirculation, 1968