Assessment of Samsung Galaxy Watch4 PPG-Based Heart Rate During Light-to-Vigorous Physical Activities
Authors:
- 31 May 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 8 (7) , 1-4
Abstract
There has been lately a notable increase in the adoption of smartwatches and fitness trackers. These wearables have gained popularity by monitoring vital health parameters, such as heart rate (HR), employing a low-cost and non-invasive technique known as photoplethysmography (PPG). Despite its ease of continuous monitoring the cardiovascular system during daily activities, PPG signal is susceptible to noise, mainly caused by user movement during monitoring, particularly in activities involving vigorous body motion. Therefore, it is crucial that PPG-based devices undergo scientific validation to ensure their reliability and accuracy in real-world conditions. In this study, we conducted an assessment of the smartwatch Samsung Galaxy Watch4 (SGW4), comparing its performance with the Polar H10, an ECG device acknowledged as the reference for HR measurement during intense activities with intense body movements. Our research protocol involved 14 participants engaged in activities that induced a range of HR variations, covering light, moderate and vigorous intensities, including stationary cycling and treadmill workouts. We employed five metrics to compare HR measurements obtained from the SGW4 with those from the reference device. Additionally, a Bland-Altman analysis was conducted to evaluate the agreement between the two devices. The results of our study indicate that the SGW4 is well-suited for accurately measuring HR during usual exercises, spanning from low to high-intensity physical activities, and considering scenarios in which the SGW4 was either nearly stationary or in free movement.Keywords
This publication has 17 references indexed in Scilit:
- Comparative Assessment of Smartwatch Photoplethysmography AccuracyIEEE Sensors Letters, 2023
- Accuracy of the Apple Watch Series 6 and the Whoop Band 3.0 for assessing heart rate during resistance exercisesJournal of Sports Sciences, 2022
- Engineering digital biomarkers of interstitial glucose from noninvasive smartwatchesnpj Digital Medicine, 2021
- Pre-symptomatic detection of COVID-19 from smartwatch dataNature Biomedical Engineering, 2020
- Wearable monitoring of sleep-disordered breathing: estimation of the apnea–hypopnea index using wrist-worn reflective photoplethysmographyScientific Reports, 2020
- RR interval signal quality of a heart rate monitor and an ECG Holter at rest and during exerciseEuropean Journal of Applied Physiology, 2019
- Stress detection in daily life scenarios using smart phones and wearable sensors: A surveyJournal of Biomedical Informatics, 2019
- Multi-Wavelength Photoplethysmography Enabling Continuous Blood Pressure Measurement With Compact Wearable ElectronicsIEEE Transactions on Biomedical Engineering, 2018
- Wearable sensors: can they benefit patients with chronic kidney disease?Expert Review of Medical Devices, 2017
- A Motion-Tolerant Adaptive Algorithm for Wearable Photoplethysmographic BiosensorsIEEE Journal of Biomedical and Health Informatics, 2013