Microfabricated passive vapor preconcentrator/injector designed for microscale gas chromatography
- 9 January 2012
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 12 (4) , 717-724
Abstract
The design, fabrication, and preliminary testing of a micromachined-Si passive vapor preconcentrator/injector (μPPI) are described. Intended for incorporation in a gas chromatographic microsystem (μGC) for analyzing organic vapor mixtures, the μPPI captures vapors from the air at a known rate by means of passive diffusion (i.e., without pumping) and then desorbs the vapor sample thermally by means of an integrated heater and injects it downstream (with pumping). The μPPI chip comprises a 1.8 μL deep reactive-ion-etched (DRIE) Si cavity with a resistively heated membrane floor and a DRIE-Si cap containing >1500 parallel diffusion channels, each 54 × 54 × 200 μm. The cavity is packed with 750 μg of a commercial graphitized carbon adsorbent. Fluidic and heat-transfer modeling was used to guide the design process to ensure power-efficient sample transfer during thermal desorption. Experiments performed with toluene at concentrations of ∼1 ppm gave a constant sampling rate of 9.1 mL min−1 for up to 30 min, which is within 2% of theoretical predictions and corresponds to a linear dynamic mass uptake range of ∼1 μg. The cavity membrane could be heated to 250 °C in 0.23 s with 1 W of applied power and, with 50 mL min−1 of suction flow provided by a downstream pump, yielded >95% desorption/injection efficiency of toluene samples over an 8-fold range of captured mass.Keywords
This publication has 22 references indexed in Scilit:
- Microfabricated Gas Chromatograph for the Selective Determination of Trichloroethylene Vapor at Sub-Parts-Per-Billion Concentrations in Complex MixturesAnalytical Chemistry, 2011
- Micro gas preconcentrator in porous silicon filled with a carbon absorbentSensors and Actuators B: Chemical, 2010
- Real-time monitoring of sub-ppb concentrations of aromatic volatiles with a MEMS-enabled miniaturized gas-chromatographSensors and Actuators B: Chemical, 2009
- MEMS-based multi-inlet/outlet preconcentrator coated by inkjet printing of polymer adsorbentsSensors and Actuators B: Chemical, 2008
- Sub-ppm gas sensor detection via spiral μ-preconcentratorSensors and Actuators B: Chemical, 2008
- Microfabricated vapor preconcentrator for portable ion mobility spectroscopySensors and Actuators B: Chemical, 2007
- Microfabricated preconcentrator-focuser for a microscale gas chromatographJournal of Microelectromechanical Systems, 2003
- A sensitive and selective assay of nucleic acids by measuring enhanced total internal reflected resonance light scattering signals deriving from the evanescent field at the water/tetrachloromethane interfaceElectronic Supplementary Information (ESI) available: Figs. S1 and S2. See http://www.rsc.org/suppdata/an/b2/b204141n/The Analyst, 2002
- Evaluation of a Passive Sampler for Volatile Organic Compounds at ppb Concentrations, Varying Temperatures, and Humidities with 24-h Exposures. 2. Sampler PerformanceEnvironmental Science & Technology, 1999
- Performance of fixed-bed catalytic reactors with poison in the feedJournal of Catalysis, 1969