End digit preference in blood pressure measurement in a hypertension specialty clinic in southwest Nigeria
Authors:
- O.E. AyodeleOAO.E. Ayodele
- E.O. SanyaESE.O. Sanya
- O.O. OkunolaOOO.O. Okunola
- A.A. AkintundeAAA.A. Akintunde
Open Access
- 13 March 2012
- journal article
- research article
- Published by Clinics Cardive Publishing in CardioVascular Journal of Africa
- Vol. 23 (2) , 85-89
Abstract
One of the observer errors associated with blood pressure (BP) measurement using a mercury sphygmomanometer is end digit preference (EDP) which refers to the occurrence of a particular end digit more frequently than would be expected by chance alone. Published reports, mainly from outside Africa, have shown a high prevalence ranging from 22 to 90% of end digit zero in BP readings taken by healthcare workers (HCWs). This study examined the prevalence of EDP and patients' and physicians' characteristics influencing the occurrence of EDP. A retrospective review was undertaken of BP readings of 114 patients seen over a two-month period at our hypertension specialty clinic. Nurses and physicians displayed a high frequency of preference for end digit zero in systolic blood pressure (SBP) and diastolic blood pressure (DBP) readings. The preference for end digit zero was, however, higher for nurses than for physicians (SBP: 98.5 vs 51.2%, p < 0.001; DBP: 98.5 vs 64.3%, p < 0.001). Among the physicians, the consultant staff displayed the least preference for end digit zero compared to resident doctors. There was no statistically significant difference in gender, age, weight, height and BMI of those with BP readings with end digit zero compared with those with non-zero end digits. The high prevalence of EDP for zero argues for the training, retraining and certification of HCWs in BP measurement and the institution of a regular monitoring and feedback system on EDP in order to minimise this observer error.Keywords
This publication has 30 references indexed in Scilit:
- Blood pressure recording bias during a period when the Quality and Outcomes Framework was introducedJournal of Human Hypertension, 2009
- Guidelines for management of hypertension: report of the fourth working party of the British Hypertension Society, 2004—BHS IVJournal of Human Hypertension, 2004
- Terminal digit bias in a specialty hypertension faculty practiceJournal of Human Hypertension, 2003
- The Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood PressureThe JNC 7 ReportJAMA, 2003
- Selective recording in blood pressure readings may increase subsequent mortality.QJM: An International Journal of Medicine, 2002
- Terminal digit preference and single-number preference in the Syst-Eur trial: influence of quality controlBlood Pressure Monitoring, 2002
- Effects of terminal digit preference on the proportion of treated hypertensive patients achieving target blood pressuresJournal of Human Hypertension, 2001
- Measurement of blood presssure: an evidence based reviewBMJ, 2001
- Mercury Sphygmomanometers Should Not be Abandoned: An Advisory Statement From the Council for High Blood Pressure Research, American Heart AssociationHypertension, 2001
- The mercury sphygmomanometer should be abandoned before it is proscribedJournal of Human Hypertension, 2000