Changes in Corneal Volume at Different Areas and Its Correlation with Corneal Biomechanics after SMILE and FS-LASIK Surgery
Open Access
- 27 April 2020
- journal article
- research article
- Published by Wiley in Journal of Ophthalmology
- Vol. 2020, 1-7
Abstract
Purpose. To investigate the variations of corneal volume (CV) after small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) and analyze the influences of biomechanical properties on the changes of refraction and CV.Methods. Ninety-seven eyes of 97 patients undergoing SMILE and FS-LASIK were included in this retrospective study. CV was measured with Scheimpflug-based corneal topography at preoperatively and at day 1, week 1, and months 1 and 3 postoperatively. CV measured within 5 mm diameter was defined as central region volume (CV5) and between 5 mm and 10 mm diameter was defined as peripheral region volume (CV5-10). An Ocular Response Analyzer (ORA) was used to assess corneal biomechanical properties including corneal hysteresis (CH) and corneal resistant factor (CRF). The reduction of study parameters (△) were calculated by subtracting the preoperative value at various time points from the postoperative values.Results. CV had significant reduction after the SMILE and FS-LASIK procedure (). CV5 increased significantly from postoperative day 1 to month 3 () in SMILE, while both CV5 and CV5-10 increased significantly in FS-LASIK (). The increase in CV5 after SMILE was 0.11 ± 0.16 mm3,which was significantly different from FS-LASIK (0.20 ± 0.13 mm3,). In the SMILE group, △CV5 correlated with △CRF (r = 0.498,) and △CH (r = 0.374,). In the FS-LASIK group, △CV5 and △CRF had a significant correlation (r = 0.363,), but not with △CH.Conclusions. Dynamic changes in corneal volume were found after SMILE and FS-LASIK surgery. The central region significantly increased after SMILE, while both central and peripheral regions increased following FS-LASIK in the early postoperative period. SMILE was associated with less change in biomechanical properties per unit of reduction in CV compared with FS-LASIK.
Keywords
Funding Information
- National Natural Science Foundation of China (81670884, 81873684)
- National Natural Science Foundation of China (81670884, 81873684)
This publication has 28 references indexed in Scilit:
- The biomechanical properties of the cornea and anterior segment parametersBMC Ophthalmology, 2013
- Early Corneal Wound Healing and Inflammatory Responses after Refractive Lenticule Extraction (ReLEx)Investigative Ophthalmology & Visual Science, 2011
- Pentacam Scheimpflug Evaluation of Corneal Volume After LASIKJournal of Refractive Surgery, 2010
- Corneal biomechanical measurements before and after laser in situ keratomileusisJournal of Cataract & Refractive Surgery, 2008
- Evaluation of anterior segment parameters in keratoconic eyes measured with the Pentacam systemJournal of Cataract & Refractive Surgery, 2007
- The Safety of 250 µm Residual Stromal Bed in Preventing Keratectasia after Laser in situ Keratomileusis (LASIK)Journal of Korean Medical Science, 2007
- Corneal-thickness spatial profile and corneal-volume distribution: Tomographic indices to detect keratoconusJournal of Cataract & Refractive Surgery, 2006
- Biomechanics and wound healing in the corneaExperimental Eye Research, 2006
- Phacoemulsification Associated Corneal Damage Evaluated by Corneal VolumeAmerican Journal of Ophthalmology, 2006
- Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetryJournal of Cataract & Refractive Surgery, 2005