Optimization of electrospray interface and quadrupole ion trap mass spectrometer parameters in pesticide liquid chromatography/electrospray ionization mass spectrometry analysis
- 9 March 2010
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 24 (7) , 919-926
Abstract
Optimization of both the ionization process and ion transportation in the mass spectrometer is of crucial importance in order to achieve high sensitivity and low detection limits and acceptable accuracy in liquid chromatography/electrospray ionization mass spectrometry (LC/ESI‐MS) analysis. In this paper four optimization procedures of electrospray interface and quadrupole ion‐trap mass spectrometer parameters (ESI‐MS) (nebulizer gas and drying gas flow rate, end plate voltage, capillary voltage, skimmer voltage, octopoles direct current and radio frequency, trap drive and lens voltages) were studied on three pesticides – thiabendazole, aldicarb and imazalil. The results demonstrate that the methodology of optimization strongly influences the effectiveness of finding true optima of the operating parameters. Both eluent flow rate and composition during optimization have to mimic the situation during real analysis as closely as possible in order to achieve parameters giving the highest sensitivity. Therefore, post‐column addition of analyte to the mobile phase identical in composition to the one in which analyte elutes during real analysis combined with software‐based optimization was found to be the most effective and fastest method for achieving intensity maxima. The parameters most strongly affecting ion formation and transportation, hence sensitivity, were capillary voltage, direct current of the first octopole, trap drive and the second lens for all pesticides under study. In addition to sensitivity and detection limit matrix effect was considered in the optimization process. It was found that the matrix effect can be reduced but not eliminated by adjusting the ESI and MS parameters. The optimal parameters from the point of view of the matrix effect can only be found with factorial design. Parameters giving higher sensitivity tended to be more affected by matrix effect causing higher ionization suppression by co‐eluting compounds. Copyright © 2010 John Wiley & Sons, Ltd.Keywords
This publication has 14 references indexed in Scilit:
- Evaluation of signal and noise and identification of a suitable target function in the tuning of an ESI ion trap mass spectrometer by multivariate pattern recognition toolsJournal of the American Society for Mass Spectrometry, 2009
- Comparing solid phase extraction and direct injection for the analysis of ultra-trace levels of relevant explosives in lake water and tributaries using liquid chromatography–electrospray tandem mass spectrometryChemosphere, 2008
- Matrix effects in pesticide multi-residue analysis by liquid chromatography–mass spectrometryJournal of Chromatography A, 2008
- Optimization of the ESI and APCI experimental variables for the LC/MS determination of s-triazines, methylcarbamates, organophosphorous, benzimidazoles, carboxamide and phenylurea compounds in orange samplesJournal of Mass Spectrometry, 2007
- Matrix effects in quantitative pesticide analysis using liquid chromatography–mass spectrometryMass Spectrometry Reviews, 2006
- In electrospray ionization, how much pull does an ion need to escape its droplet prison?Journal of the American Society for Mass Spectrometry, 1997
- Determination of pesticide residues in fruit and vegetablesJournal of Chromatography A, 1996
- Electrospray interface for liquid chromatographs and mass spectrometersAnalytical Chemistry, 1985
- Field induced ion evaporation from liquid surfaces at atmospheric pressureThe Journal of Chemical Physics, 1979
- On the evaporation of small ions from charged dropletsThe Journal of Chemical Physics, 1976