Hybrid Active Filter With Variable Conductance for Harmonic Resonance Suppression in Industrial Power Systems
- 12 August 2014
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 62 (2) , 746-756
Abstract
Unintentional series and/or parallel resonances, due to the tuned passive filter and the line inductance, may result in severe harmonic distortion in the industrial power system. This paper presents a hybrid active filter to suppress harmonic resonance and to reduce harmonic distortion. The proposed hybrid filter is operated as variable harmonic conductance according to the voltage total harmonic distortion; therefore, harmonic distortion can be reduced to an acceptable level in response to load change or parameter variation of the power system. Since the hybrid filter is composed of a seventh-tuned passive filter and an active filter in series connection, both dc voltage and kVA rating of the active filter are dramatically decreased compared with the pure shunt active filter. In real application, this feature is very attractive since the active power filter with fully power electronics is very expensive. A reasonable tradeoff between filtering performances and cost is to use the hybrid active filter. Design consideration are presented, and experimental results are provided to validate effectiveness of the proposed method. Furthermore, this paper discusses filtering performances on line impedance, line resistance, voltage unbalance, and capacitive filters.Keywords
Funding Information
- Ministry of Science and Technology, Taiwan (103-3113-E-110-002)
This publication has 39 references indexed in Scilit:
- Multiresonant Frequency-Locked Loop for Grid Synchronization of Power Converters Under Distorted Grid ConditionsIEEE Transactions on Industrial Electronics, 2010
- Control and Resonance Damping of Voltage-Source and Current-Source Converters With $LC$ FiltersIEEE Transactions on Industrial Electronics, 2008
- Digital Current Control of a Voltage Source Converter With Active Damping of LCL ResonanceIEEE Transactions on Power Electronics, 2006
- Design and Control of an LCL-Filter-Based Three-Phase Active RectifierIEEE Transactions on Industry Applications, 2005
- Analysis of Multiloop Control Strategies for LC/CL/LCL-Filtered Voltage-Source and Current-Source InvertersIEEE Transactions on Industry Applications, 2005
- Harmonic Interaction Between a Large Number of Distributed Power Inverters and the Distribution NetworkIEEE Transactions on Power Electronics, 2004
- Implementation and performance of cooperative control of shunt active filters for harmonic damping throughout a power distribution systemIEEE Transactions on Industry Applications, 2003
- Assessment of voltage unbalanceIEEE Transactions on Power Delivery, 2001
- Hybrid solutions for improving passive filter performance in high power applicationsIEEE Transactions on Industry Applications, 1997
- A novel control to actively damp resonance in input LC filter of a three-phase voltage source converterIEEE Transactions on Industry Applications, 1997