Coronary artery bypass graft markers: history, usage, and effects
Authors:
- 7 March 2020
- journal article
- review article
- Published by Springer Nature in General Thoracic and Cardiovascular Surgery
- Vol. 68 (5) , 453-458
Abstract
Coronary artery bypass grafting (CABG) is one of the most common procedures in the United States as many Americans suffer from coronary heart disease and undergo CABG each year. While CABG has been performed for decades, questions remain regarding the benefits graft marker placement provides for patient therapy and outcomes. Markers at the proximal graft anastomosis aim to improve the efficiency and reduce the risks of subsequent, post-coronary artery bypass grafting coronary angiography by decreasing fluoroscopy time and contrast volume used. Graft markers have been shown to reduce fluoroscopy time and contrast volume, but concerns exist regarding their potentially negative impact on patient outcomes by increasing procedural time and possibly affecting graft patency. The relationship between graft markers and graft patency has not been studied in depth, and there is little evidence to show that graft patency is determined by graft marker placement. Because of the potential benefits to patients and the limited risks, it is important to continue studying graft marker usage and their effects on long-term outcomes.Keywords
This publication has 53 references indexed in Scilit:
- Prevalence of Aortocoronary Graft Marker Use and the Factors Affecting This DecisionJournal of Cardiac Surgery, 2010
- New Discussion on an Old Subject: Proximal Anastomosis Markers in Coronary Bypass SurgeryThe Annals of Thoracic Surgery, 2008
- Impact on Contrast, Fluoroscopy, and Catheter Utilization from Knowing the Coronary Artery Bypass Graft Anatomy Before Diagnostic Coronary AngiographyThe American Journal of Cardiology, 2008
- Impact of Saphenous Vein Graft Radiographic Markers on Clinical Events and Angiographic ParametersThe Annals of Thoracic Surgery, 2008
- Non-invasive assessment of coronary artery bypass graft patency using 16-slice computed tomography angiographyJournal of Cardiothoracic Surgery, 2007
- Relation of Early Saphenous Vein Graft Failure to Outcomes Following Coronary Artery Bypass SurgeryThe American Journal of Cardiology, 2005
- Long-term patency of saphenous vein and left internal mammary artery grafts after coronary artery bypass surgeryJACC, 2004
- Coronary artery bypass grafts: New universal markersCatheterization and Cardiovascular Diagnosis, 1989
- Stainless Steel Markers for Aorta–Saphenous Vein AnastomosisThe Annals of Thoracic Surgery, 1978
- A Metal Ring Marker for the Proximal End of an Aorta-to-Coronary Artery GraftThe Annals of Thoracic Surgery, 1973