Uptake calibration of polymer-based passive samplers for monitoring priority and emerging organic non-polar pollutants in WWTP effluents
- 18 February 2016
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 408 (12) , 3165-3175
Abstract
The uptake calibration of more than 12 non-polar organic contaminants by 3 polymeric materials is shown: bare polydimetilsiloxane (PDMS, stir-bars), polyethersulfone tubes and membranes (PES) and polyoxymethylene membranes (POM), both in their free form and membrane-enclosed sorptive coating (MESCO). The calibration process was carried out exposing the samplers to a continuous flow of contaminated water at 100 ng mL−1 for up to 28 days, and, consequently, the sampling rates (Rs, mL day−1) of several organic microcontaminants were provided for the first time. In situ Rs values were also determined disposing the samplers in the effluent of a wastewater treatment plant. Finally, these passive samplers were applied to monitor the effluents of two wastewater treatment plants. This application lead to the confirmation of the presence of galaxolide, tonalide and 4-tert-octylphenol at high ng mL−1 levels, as well as the identification of compounds like some phthalates and alkylphenols at levels below the detection limits for active sampling methods.Keywords
This publication has 30 references indexed in Scilit:
- Assessment of the environmental status of the coastal and marine aquatic environment in Europe: A plea for adaptive managementEstuarine, Coastal and Shelf Science, 2012
- Calibration of the Chemcatcher® passive sampler for monitoring selected polar and semi-polar pesticides in surface waterEnvironmental Pollution, 2008
- Passive sampling in environmental analysisJournal of Chromatography A, 2008
- Polymer selection for passive sampling: A comparison of critical propertiesChemosphere, 2007
- Air–water distribution of hexachlorobenzene and 4,4′-DDE along a North–South Atlantic transectMarine Pollution Bulletin, 2007
- Modelling and field application of the Chemcatcher passive sampler calibration data for the monitoring of hydrophobic organic pollutants in waterEnvironmental Pollution, 2007
- Rapid semi-continuous calibration and field test of membrane-enclosed silicone collector as passive water samplerJournal of Chromatography A, 2006
- Passive sampling techniques for monitoring pollutants in waterTrAC Trends in Analytical Chemistry, 2005
- Non-regulated water contaminants: emerging researchEnvironmental Impact Assessment Review, 2004
- Peer Reviewed: Equilibrium Sampling DevicesEnvironmental Science & Technology, 2003