Abstract
Objectives: We aimed to compare the amount of radiation exposure that was produced during computed tomography (CT)-control versus O-arm control of pedicle screw placement during degenerative lumbar spine surgery. Patients and methods: Between November 2013 and August 2021, 358 patients (O-arm + neuronavigation) group (154 males, 204 females; mean age: 61.4±12.3 years; range, 40 to 84 years) who underwent spinal surgery were included in the study. All patients in this group underwent surgery with intraoperative O-arm CT and neuronavigation assistance. The control (fluroscopy + CT-control) group consisted of 124 patients (50 males, 74 females; mean age: 63.9±11.9 years; range, 49 to 72 years) who underwent lumbar spinal stabilization surgery for adult degenerative lumbar disease under fluoroscopy and postoperative CT-control. All data were collected retrospectively. Kolmogorov-Smirnov test was employed to test whether radiation dose values exerted an equal distribution. Following the detection that these values did not distribute equally, a Mann-Whitney test was used to test the significance. Results: Patients operated with intraoperative O-arm CT and neuronavigation assistance did not require any revision surgery. Median radiation exposure per patient was calculated as 1108.4 and 838 mGycm for control (CT-control) and study (O-arm) groups, respectively. Mann-Whitney test revealed a significant difference in reduced radiation exposure with O-arm (z: –6.056, asymptotic significance (2-tailed) pConclusion: We advocate the routine use of intraoperative O-arm imaging and neuronavigation particularly in degenerative spinal surgery due to both reduced radiation exposure and providing more precise screw placement.Keywords
This publication has 10 references indexed in Scilit:
- Comparing the Efficiency, Radiation Exposure, and Accuracy Using C-Arm versus O-Arm With 3D Navigation in Placement of Transiliac–Transsacral and Iliosacral Screws: A Cadaveric Study Evaluating an Early Career SurgeonJournal of Orthopaedic Trauma, 2020
- Does Pedicle Screw Fixation Assisted by O-Arm Navigation Perform Better Than Fluoroscopy-guided Technique in Thoracolumbar Fractures in Percutaneous Surgery?Clinical Spine Surgery, 2020
- X-ray exposure in odontoid screwing for Anderson type II fracture: comparison between O-arm and C-arm-assisted proceduresActa Neurochirurgica, 2019
- Time Demand and Radiation Dose in 3D-Fluoroscopy-based Navigation-assisted 3D-Fluoroscopy-controlled Pedicle Screw InstrumentationsSpine, 2018
- Intraoperative radiation exposure in spinal scoliosis surgery for pediatric patients using the O-arm® imaging systemEuropean Journal of Orthopaedic Surgery & Traumatology, 2018
- Radiation exposure in spine surgery using an image-guided system based on intraoperative cone-beam computed tomography: analysis of 107 consecutive casesJournal of Neurosurgery: Spine, 2016
- Radiation exposure using the O-arm® surgical imaging systemEuropean Spine Journal, 2016
- Commentary: Utility of the O-Arm in spinal surgerySurgical Neurology International, 2014
- Dose optimisation for intraoperative cone-beam flat-detector CT in paediatric spinal surgeryPediatric Radiology, 2012
- Dosimetric characterization of a cone-beam O-arm™ imaging systemJournal of X-Ray Science and Technology, 2009