Diálisis peritoneal automática adaptada: un método de prescripción eficaz, eficiente y seguro
Open Access
- 27 September 2014
- journal article
- Published by Sociedad Espanola de Enfermeria Nefrologica in Enfermería Nefrológica
- Vol. 17 (3) , 202-208
Abstract
The aim of this study is to analyze results obtained following the introduction of the adapted automated peritoneal dialysis, in a group of patients in conventional automated peritoneal dialysis program using bicarbonate-buffered dialysate. Design trial in experimental phase, which was conducted in the months from February and December 2013, in the unit of peritoneal dialysis in the Hospital Clinic of Barcelona. Study subjects were 12 patients, 7 women and 5 men, in conventional automated peritoneal dialysis modality. Mean age 58±12 years (range: 34-71). The study assessed two automated peritoneal dialysis prescriptions. This study was started with conventional dialysis for three months. Then, dialysis prescription was modified, and adapted was applied during same interval of time. And finally, conventional dialysis for three months. The same total volume of dialysate, the same duration, and the same 1,5% glucose bicarbonatebuffered dialysate, were prescribed in both modalities. Only dwell time and fill volume were modified, when dialysis modality was changed. All patients, on dry day. Variables at the beginning of the study, and at each change of prescription were seldom monitored. Outcomes for conventional dialysis: Kt/v=2,3±0,2, creatinine clearance=63±8l/week, and ultrafiltration=842±110ml. For dialysis adapted, Kt/v=2,8±0,2, creatinine clearance=74±9l/week, and ultrafiltration=982±123ml. Adapted dialysis allows appropriate treatment efficiency, improves adequacy of dialysis and ultrafiltration parameters; being safe and comfortable for the patient.Keywords
This publication has 9 references indexed in Scilit:
- The impact of neutral-pH peritoneal dialysates with reduced glucose degradation products on clinical outcomes in peritoneal dialysis patientsKidney International, 2013
- Optimizing peritoneal dialysis prescription for volume control: the importance of varying dwell time and dwell volumePediatric Nephrology, 2013
- The Beneficial Influence on the Effectiveness of Automated Peritoneal Dialysis of Varying the Dwell Time (Short/Long) and Fill Volume (Small/Large): A Randomized Controlled TrialPeritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis, 2011
- Long-Term Clinical Experience with Pure Bicarbonate Peritoneal Dialysis SolutionsPeritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis, 2006
- Effect of Kt/V on survival and clinical outcome in CAPD patients in a randomized prospective studyKidney International, 2003
- Measurement of hydrostatic intraperitoneal pressure: a useful tool for the improvement of dialysis dose prescriptionPediatric Nephrology, 2003
- Effect of Increased Dialysate Volume on Peritoneal Surface Area among Peritoneal Dialysis PatientsJournal of the American Society of Nephrology, 2002
- Peritoneal Dialysis Fill Volume: Can the Patient Tell the Difference?Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis, 2001
- Peritoneal Sodium Mass Removal in Continuous Ambulatory Peritoneal Dialysis and Automated Peritoneal Dialysis: Influence on Blood Pressure ControlAmerican Journal of Nephrology, 2001