Using Field Measured Transient Responses in a Water Distribution System to Assess Valve Status and Network Topology
- 1 July 2005
- conference paper
- Published by American Society of Civil Engineers (ASCE)
- p. 1-12
Abstract
Uncertainty about the status of valves in a water distribution system, or the existence of total blockages, is not uncommon. This paper presents an approach for determining topological changes using transient response analysis. Precise information is not available regarding all the physical elements contributing to the transient response of a water distribution system. Thus a parameterised model is developed and calibrated to represent "real" transient responses from a field water distribution system. The robustness of this model, and the methodology for diagnosing topological changes, are confirmed when used to successfully identify closed valves in the field.Keywords
This publication has 4 references indexed in Scilit:
- The dynamic effect of pipe-wall viscoelasticity in hydraulic transients. Part II—model development, calibration and verificationJournal of Hydraulic Research, 2005
- Field Tests for Leakage, Air Pocket, and Discrete Blockage Detection Using Inverse Transient Analysis in Water Distribution Pipes2004
- Transients in Distribution Networks: Field Tests and Demand ModelsJournal of Hydraulic Engineering, 1995
- Inverse Transient Analysis in Pipe NetworksJournal of Hydraulic Engineering, 1994