Intelligent Tool for Determining the True HarmonicCurrent Contribution of a Customer in a Power Distribution Network
Authors:
- 19 September 2008
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 44 (5) , 1477-1485
Abstract
Customer loads connected to power distribution network may be broadly categorized as either linear or nonlinear. Nonlinear loads inject harmonics into the power network. Harmonics in a power system are classified as either load harmonics or as supply harmonics depending on their origin. The source impedance also impacts the harmonic current flowing in the network. Hence, any change in the source impedance is reflected in the harmonic spectrum of the current. This paper proposes a novel method based on artificial neural networks to isolate and evaluate the impact of the source impedance change without disrupting the operation of any load, by using actual field data. The test site chosen for this paper has a significant amount of triplen harmonics in the current. By processing the acquired data with the proposed algorithm, the actual load harmonic contribution of the customer is predicted. Experimental results confirm that attempting to predict the total harmonic distortion of a customer by simply measuring the customer's current may not be accurate. The main advantage of this method is that only waveforms of voltages and currents at the point of common coupling have to be measured. This method is applicable for both single- and three-phase loads.Keywords
This publication has 13 references indexed in Scilit:
- Harmonic convergenceIEEE Industry Applications Magazine, 2006
- System and method for determining harmonic contributions from non-linear loads2005
- Operations of the dominant harmonic active filter (DHAF) under realistic utility conditionsIEEE Transactions on Industry Applications, 2001
- A method for determining customer and utility harmonic contributions at the point of common couplingIEEE Transactions on Power Delivery, 2000
- Power quality following deregulationProceedings of the IEEE, 2000
- Reducing the computational demands of continually online-trained artificial neural networks for system identification and control of fast processesIEEE Transactions on Industry Applications, 1998
- On separating customer and supply side harmonic contributionsIEEE Transactions on Power Delivery, 1996
- Harmonic analysis for industrial customersIEEE Transactions on Industry Applications, 1994
- A practical approach to harmonic compensation in power systems-series connection of passive and active filtersIEEE Transactions on Industry Applications, 1991
- What Size Net Gives Valid Generalization?Neural Computation, 1989