Effect of transfemoral prosthetic socket interface design on gait, balance, mobility, and preference: A randomized clinical trial
Authors:
- 23 March 2021
- journal article
- research article
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 45 (4) , 304-312
Abstract
Background: There are alternative transfemoral (TF) socket interface designs that have not been compared with the standard of care, ischial ramus containment (IRC). The interface directly affects performance. Objectives: To compare 3 TF interface designs, IRC, dynamic socket (DS), and subischial (Sub-I), regarding gait, balance, mobility, and preference. The authors hypothesized that these more active users may experience gait, mobility, and preference benefits from the less intrusive DS and Sub-I interface designs. Study Design: Single-blind, repeated-measures, 3-period randomized controlled crossover clinical trial. Methods: People with unilateral TF amputation with 1 year or longer prosthesis use experience, independent community ambulatory status, 18 to 60 years of age, of any race or ethnicity, with a body mass of 45 to 125 kg, and with a self-reported ability to walk for 20 minutes continuously were included in the study. Each participant was fit in all 3 interface designs. Results: Thirteen participants completed the clinical trial. Velocity, cadence, mobility, and balance were not statistically different between the 3 socket conditions. The DS demonstrated significantly greater symmetry in swing, stance, single support percentage, and toe angle compared with IRC and Sub-I. Sixty days after study completion, 7 participants changed interfaces, trending away from IRC. Conclusions: Large differences were not observed. Small differences in spatiotemporal gait measures combined with patient preference may make a meaningful difference to individual patients and should be considered.Keywords
This publication has 43 references indexed in Scilit:
- Reliability of Outcome Measures for People With Lower-Limb Amputations: Distinguishing True Change From Statistical ErrorPhysical Therapy, 2011
- Prosthetic sockets stabilized by alternating areas of tissue compression and releaseJournal of Rehabilitation Research and Development, 2011
- Evaluation of gait symmetry after stroke: A comparison of current methods and recommendations for standardizationGait & Posture, 2010
- Differences in the Spatiotemporal Parameters of Transtibial and Transfemoral Amputee GaitJPO Journal of Prosthetics and Orthotics, 2010
- Comparison of nonmicroprocessor knee mechanism versus C-Leg on Prosthesis Evaluation Questionnaire, stumbles, falls, walking tests, stair descent, and knee preferenceJournal of Rehabilitation Research and Development, 2008
- The Reliability and Validity of the Four Square Step Test for People With Balance Deficits Secondary to a Vestibular DisorderArchives of Physical Medicine and Rehabilitation, 2007
- Reproducibility of Physical Performance and Physiologic AssessmentsJournal of Aging and Health, 2005
- Fear of falling and postural control in Parkinson's diseaseMovement Disorders, 2003
- The MicroFrame: The Next Generation of Interface Design for Glenohumeral Disarticulation and Associated Levels of Limb DeficiencyJPO Journal of Prosthetics and Orthotics, 2003
- A Case Study Using Fluoroscope to Determine the Vital Elements of Transfemoral Interface DesignJPO Journal of Prosthetics and Orthotics, 2002