Evaluation of Hand Sensibility with Single and Double Latex Gloves
Authors:
- 1 January 1999
- journal article
- research article
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery
- Vol. 103 (1) , 128-131
Abstract
The purpose of this study was to examine hand sensibility of surgeons wearing single and double latex gloves. Evaluation of hand sensibility, including cutaneous pressure thresholds, moving two-point discrimination, and static two-point discrimination, was performed on 25 surgeons (mean age 45 years). The dominant hand index finger was assessed with no glove, single glove, and double glove. The majority of surgeons had a moving and static two-point discrimination of 2 or 3 mm. The lowest cutaneous pressure thresholds were found when measured with no gloves and increased with single and double gloves. Statistically significant differences in cutaneous pressure thresholds using Semmes-Weinstein monofilaments were found for gloves versus no gloves (p < 0.0003) and single versus double gloves (p = 0.0003). Statistically significant differences in moving two-point discrimination were found for no gloves versus double gloves (p = 0.05) and single versus double gloves (p = 0.02). In conclusion, we found significant differences in hand sensation when measured with single and double gloves. (Plast. Reconstr. Surg. 103: 128, 1999.)Keywords
This publication has 15 references indexed in Scilit:
- Surgeons' Concern and Practices of Protection Against Bloodborne PathogensAnnals of Surgery, 1998
- Practical Precautions for Avoiding Sharp Injuries and Blood ExposurePlastic and Reconstructive Surgery, 1998
- Does Double Gloving Protect Surgical Staff from Skin Contamination during Plastic Surgery?Plastic and Reconstructive Surgery, 1997
- Establishment of Reliability in the Evaluation of Hand SensibilityPlastic and Reconstructive Surgery, 1993
- Testing Sensibility, Including Touch-Pressure, Two-point Discrimination, Point Localization, and VibrationJournal of Hand Therapy, 1993
- Surgical GlovesAORN Journal, 1992
- Does wearing two pairs of gloves protect operating theatre staff from skin contamination?BMJ, 1988
- Surgical gloves as a mechanical barrier against human immunodeficiency virusesBritish Journal of Surgery, 1988
- Reliability of two-point discrimination measurementsThe Journal of Hand Surgery, 1987
- Von Frey's method of measuring pressure sensibility in the hand: An engineering analysis of the Weinstein-Semmes pressure aesthesiometerThe Journal of Hand Surgery, 1978