Large-Area, High-Resolution Birefringence Imaging with Polarization-Sensitive Fourier Ptychographic Microscopy
- 7 January 2021
- journal article
- letter
- Published by American Chemical Society (ACS) in ACS Photonics
- Vol. 8 (1) , 158-165
Abstract
We present polarization-sensitive Fourier ptychographic microscopy (PS-FPM) capable of generating high-resolution birefringence images of optically anisotropic specimens over a large field of view (FoV). FPM produces high-resolution images of transparent samples over a large FoV based on multiple intensity measurements acquired at various illumination angles and ptychographic phase retrieval. We combine this attractive feature of FPM with a single-input-state illumination and polarization-diverse imaging system to achieve the imaging of both complex and birefringence information on transparent objects. Compared to conventional polarization imaging techniques, PS-FPM does not involve any mechanical rotation of the polarizer/analyzer and achieves birefringence imaging with a half-pitch resolution of 0.55 μm over 3.78 mm2 FoV, which corresponds to the space-bandwidth product of 12.5 megapixels. We demonstrate the high-resolution, large-area birefringence imaging capability of PS-FPM by presenting the birefringence images of various anisotropic objects including monosodium urate, Tilia stem, and hemozoin crystals.Keywords
Funding Information
- Samsung (SRFC-IT2002-07)
- National Research Foundation of Korea (2020R1A2C201206111)
This publication has 48 references indexed in Scilit:
- Birefringence microscopy platform for assessing airway smooth muscle structure and function in vivoScience Translational Medicine, 2016
- Introduction to Liquid Crystals for Optical Design and Engineering2015
- Compensation and control of the birefringence of polymers for photonicsPolymer Journal, 2012
- A polarized light microscopy method for accurate and reliable grading of collagen organization in cartilage repairOsteoarthritis and Cartilage, 2011
- Imaging linear birefringence and dichroism in cerebral amyloid pathologiesProceedings of the National Academy of Sciences, 2003
- Automated detection of foveal fixation by use of retinal birefringence scanningApplied Optics, 1999
- Birefringence of Single and Bundled MicrotubulesBiophysical Journal, 1998
- Strain-induced birefringence and molecular structure of glassy polymersPolymer, 1997
- Optical Measurement of the Contributions of Colloidal Forces to the Rheology of Concentrated SuspensionsJournal of Colloid and Interface Science, 1995
- FLOW BIREFRINGENCE AND THE STRUCTURE OF MACROMOLECULESSoviet Physics Uspekhi, 1964