Pharmacokinetic digital phantoms for accuracy assessment of image-based dosimetry in177Lu-DOTATATE peptide receptor radionuclide therapy
Authors:
- Johan GustafssonJGJohan Gustafsson
- Michael LjungbergMLMichael Ljungberg
- Katarina Sjögreen GleisnerKGKatarina Sjögreen Gleisner
Open Access
- 28 July 2015
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 60 (15) , 6131-6149
Abstract
Patient-specific image-based dosimetry is considered to be a useful tool to limit toxicity associated with peptide receptor radionuclide therapy (PRRT). To facilitate the establishment and reliability of absorbed-dose response relationships, it is essential to assess the accuracy of dosimetry in clinically realistic scenarios. To this end, we developed pharmacokinetic digital phantoms corresponding to patients treated with (177)Lu-DOTATATE. Three individual voxel phantoms from the XCAT population were generated and assigned a dynamic activity distribution based on a compartment model for (177)Lu-DOTATATE, designed specifically for this purpose. The compartment model was fitted to time-activity data from 10 patients, primarily acquired using quantitative scintillation camera imaging. S values for all phantom source-target combinations were calculated based on Monte-Carlo simulations. Combining the S values and time-activity curves, reference values of the absorbed dose to the phantom kidneys, liver, spleen, tumours and whole-body were calculated. The phantoms were used in a virtual dosimetry study, using Monte-Carlo simulated gamma-camera images and conventional methods for absorbed-dose calculations. The characteristics of the SPECT and WB planar images were found to well represent those of real patient images, capturing the difficulties present in image-based dosimetry. The phantoms are expected to be useful for further studies and optimisation of clinical dosimetry in (177)Lu PRRT.Keywords
Funding Information
- Cancerfonden
- Gunnar Nilssons Cancerstiftelse
- Vetenskapsrådet (621-2014-6187)
- Fru Berta Kamprads Stiftelse
This publication has 27 references indexed in Scilit:
- Differences in predicted and actually absorbed doses in peptide receptor radionuclide therapyMedical Physics, 2012
- The accuracy of absorbed dose estimates in tumours determined by Quantitative SPECT: A Monte Carlo studyActa Oncologica, 2011
- 177Lu‐[DOTA0,Tyr3] octreotate therapy in patients with disseminated neuroendocrine tumors: Analysis of dosimetry with impact on future therapeutic strategyCancer, 2010
- Highly Efficient In Vivo Agonist-Induced Internalization of sst2 Receptors in Somatostatin Target TissuesJournal of Nuclear Medicine, 2009
- Long-term evaluation of renal toxicity after peptide receptor radionuclide therapy with 90Y-DOTATOC and 177Lu-DOTATATE: the role of associated risk factorsEuropean Journal of Nuclear Medicine and Molecular Imaging, 2008
- NURBS-based 3-d anthropomorphic computational phantoms for radiation dosimetry applicationsRadiation Protection Dosimetry, 2007
- Results of Individual Patient Dosimetry in Peptide Receptor Radionuclide Therapy with 177 Lu DOTA-TATE and 177 Lu DOTA-NOCCancer Biotherapy and Radiopharmaceuticals, 2007
- Understanding the meaning of accuracy, trueness and precisionAccreditation and Quality Assurance, 2006
- 3D Absorbed Dose Calculations Based on SPECT: Evaluation for 111-In/90-Y Therapy using Monte Carlo SimulationsCancer Biotherapy and Radiopharmaceuticals, 2003
- Basic anatomical and physiological data for use in radiological protection: reference valuesAnnals of the ICRP, 2002