A molecularly imprinted electrochemical sensor with dual functional monomers for selective determination of gatifloxacin
- 15 June 2023
- journal article
- research article
- Published by Springer Nature in Microchimica Acta
- Vol. 190 (7) , 1-8
Abstract
A molecularly imprinted electrochemical sensor was designed for the selective determination of gatifloxacin (GTX) based on dual functional monomers. Multi-walled carbon nanotube (MWCNT) enhanced the current intensity and zeolitic imidazolate framework 8 (ZIF8) provided a large surface area to produce more imprinted cavities. In the electropolymerization of molecularly imprinted polymer (MIP), p-aminobenzoic acid (p-ABA) and nicotinamide (NA) were used as dual functional monomers, and GTX was the template molecule. Taking [Fe(CN)6]3−/4− as an electrochemical probe, an oxidation peak on the glassy carbon electrode was located at about 0.16 V (vs. saturated calomel electrode). Due to the diverse interactions among p-ABA, NA, and GTX, the MIP-dual sensor exhibited higher specificity towards GTX than MIP-p-ABA and MIP-NA sensors. The sensor had a wide linear range from 1.00 × 10−14 to 1.00 × 10−7 M with a low detection limit of 2.61 × 10−15 M. Satisfactory recovery between 96.5 and 105% with relative standard deviation from 2.4 to 3.7% in real water samples evidenced the potential of the method in antibiotic contaminant determination. Graphical abstractKeywords
Funding Information
- National Natural Science Foundation of China (No. 22274096)
This publication has 32 references indexed in Scilit:
- Copper nanoparticles incorporating a cationic surfactant-graphene modified carbon paste electrode for the simultaneous determination of gatifloxacin and pefloxacinJournal of Electroanalytical Chemistry, 2020
- Sensitive detection of ketamine with an electrochemical sensor based on UV-induced polymerized molecularly imprinted membranes at graphene and MOFs modified electrodeBiosensors and Bioelectronics, 2019
- A robust electrochemical sensing of molecularly imprinted polymer prepared by using bifunctional monomer and its application in detection of cypermethrinBiosensors and Bioelectronics, 2019
- Simultaneous quantification of gatifloxacin, moxifloxacin, and besifloxacin concentrations in cornea and aqueous humor by LC-QTOF/MS after topical ocular dosingJournal of Pharmacological and Toxicological Methods, 2017
- Electrochemical sensor based on electro-polymerization of β-cyclodextrin and reduced-graphene oxide on glassy carbon electrode for determination of gatifloxacinSensors and Actuators B: Chemical, 2016
- A novel electrochemical 4-nonyl-phenol sensor based on molecularly imprinted poly (o-phenylenediamine-co-o-toluidine)−nitrogen-doped graphene nanoribbons−ionic liquid composite filmElectrochimica Acta, 2015
- DEVELOPMENT AND VALIDATION OF LIQUID CHROMATOGRAPHIC METHOD FOR GATIFLOXACIN AND KETOROLAC TROMETHAMINE IN COMBINED DOSAGE FORMJournal of Liquid Chromatography & Related Technologies, 2012
- Occurrence and fate of quinolone and fluoroquinolone antibiotics in a municipal sewage treatment plantWater Research, 2012
- Development of an electrochemical immunoassay for detection of gatifloxacin in swine urineJournal of Zhejiang University-SCIENCE B, 2012
- Chemiluminescent Detection of Gatifloxacin Residue in MilkAnalytical Letters, 2009