Optimal Control‐Based RF Pulses Versus Classical Motion‐Encoding Strategies for In Vivo Hepatic MR Elastography Across Multiple Excitation Frequencies in Mice: Reproducibility Assessment
Open Access
- 15 September 2026
- journal article
- research article
- Published by Wiley in NMR in Biomedicine
- Vol. 39 (10) , e70395
Abstract
This study compared an optimal control (OC)–based motion‐encoding approach using radiofrequency (RF) pulses with the conventional motion‐encoding gradient (MEG) method for in vivo hepatic magnetic resonance elastography (MRE) across multiple excitation frequencies in mice, evaluating signal quality and temporal reproducibility. Eight healthy C57BL/6 mice, including four males and four females, underwent hepatic MRE at 7T at 300, 500 and 600 Hz using RARE‐based sequences: classical MEG‐MRE and optimized OC‐MRE with GRAPE‐designed RF pulses. In both sequences, motion was encoded only along the slice direction. Each mouse was scanned on days 1, 15 and 90. Reconstruction involved phase unwrapping, directional filtering and inversion with the Algebraic Inversion of Differential Equation algorithm to estimate the shear storage modulus () on the manual liver segmentation and on an automatic circular region of interest designed for statistical analyses. Signal‐to‐noise ratio (SNR), phase‐to‐noise ratio (PNR) and intra/interanimal reproducibility were quantified using ANOVA, intraclass correlation coefficients (ICC), Bland–Altman analysis and coefficients of variation (CV). OC‐MRE provided a mean twofold increase in SNR compared with MEG‐MRE (OC/MEG = 1.8–2.1 across frequencies) and higher PNR values. increased with frequency for both methods, consistent with viscoelastic behavior and showed strong intermethod agreement (mean bias < 0.05 kPa; r > 0.96, p < 0.001). Intra‐animal reproducibility was moderate at 300 Hz (ICC = 0.31–0.50) and high at 500–600 Hz (ICC > 0.75). No significant temporal changes in hepatic stiffness were observed across sessions. OC‐MRE improves signal quality while maintaining quantitative consistency with conventional MEG‐MRE. Its short echo time and absence of motion encoding gradients enhance robustness and make it a promising tool for longitudinal small‐animal studies and future clinical translation, particularly in scenarios with short transverse relaxation times (/) such as those encountered in hepatic iron overload.Keywords
Funding Information
- Agence Nationale de la Recherche (ANR‐22‐CE19‐0023‐01)
- Agence Nationale de la Recherche
- LabEx PRIMES (ANR‐11‐LABX‐0063)
This publication has 61 references indexed in Scilit:
- Comparison of laboratory tests, ultrasound, or magnetic resonance elastography to detect fibrosis in patients with nonalcoholic fatty liver disease: A meta‐analysisHepatology, 2017
- Magnetic resonance elastography is superior to acoustic radiation force impulse for the Diagnosis of fibrosis in patients with biopsy‐proven nonalcoholic fatty liver disease: A prospective studyHepatology, 2015
- DCE‐MRI of the liver: Effect of linear and nonlinear conversions on hepatic perfusion quantification and reproducibilityJournal of Magnetic Resonance Imaging, 2013
- Proton density fat‐fraction: A standardized mr‐based biomarker of tissue fat concentrationJournal of Magnetic Resonance Imaging, 2012
- Measurement of liver T1 and T2 relaxation times in an experimental mouse model of liver fibrosisJournal of Magnetic Resonance Imaging, 2012
- Magnetic resonance elastography: A reviewClinical Anatomy, 2010
- Hepatic viscoelastic parameters measured with MR elastography: Correlations with quantitative analysis of liver fibrosis in the ratJournal of Magnetic Resonance Imaging, 2007
- Noninvasive Measures of Liver FibrosisHepatology, 2006
- Magnetic resonance imaging of shear wave propagation in excised tissueJournal of Magnetic Resonance Imaging, 1998
- MR imaging of viscoelastic propertiesJournal of Magnetic Resonance Imaging, 1995