Automated Measurement of the Arteriolar-to-Venular Width Ratio in Digital Color Fundus Photographs
- 16 June 2011
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 30 (11) , 1941-1950
Abstract
A decreased ratio of the width of retinal arteries to veins [arteriolar-to-venular diameter ratio (AVR)], is well established as predictive of cerebral atrophy, stroke and other cardiovascular events in adults. Tortuous and dilated arteries and veins, as well as decreased AVR are also markers for plus disease in retinopathy of prematurity. This work presents an automated method to estimate the AVR in retinal color images by detecting the location of the optic disc, determining an appropriate region of interest (ROI), classifying vessels as arteries or veins, estimating vessel widths, and calculating the AVR. After vessel segmentation and vessel width determination, the optic disc is located and the system eliminates all vessels outside the AVR measurement ROI. A skeletonization operation is applied to the remaining vessels after which vessel crossings and bifurcation points are removed, leaving a set of vessel segments consisting of only vessel centerline pixels. Features are extracted from each centerline pixel in order to assign these a soft label indicating the likelihood that the pixel is part of a vein. As all centerline pixels in a connected vessel segment should be the same type, the median soft label is assigned to each centerline pixel in the segment. Next, artery vein pairs are matched using an iterative algorithm, and the widths of the vessels are used to calculate the AVR. We trained and tested the algorithm on a set of 65 high resolution digital color fundus photographs using a reference standard that indicates for each major vessel in the image whether it is an artery or vein. We compared the AVR values produced by our system with those determined by a semi-automated reference system. We obtained a mean unsigned error of 0.06 (SD 0.04) in 40 images with a mean AVR of 0.67. A second observer using the semi-automated system obtained the same mean unsigned error of 0.06 (SD 0.05) on the set of images with a mean AVR of 0.66. The testing data and reference standard used in this study has been made publicly available.Keywords
This publication has 25 references indexed in Scilit:
- A Web-Based System for the Quantitative and Reproducible Assessment of Clinical Indexes From the Retinal VasculatureIEEE Transactions on Biomedical Engineering, 2010
- Improvements in retinal vessel clustering techniques: towards the automatic computation of the arterio venous ratioComputing, 2010
- Information Fusion for Diabetic Retinopathy CAD in Digital Color Fundus PhotographsIEEE Transactions on Medical Imaging, 2009
- An improved system for the automatic estimation of the Arteriolar-to-Venular diameter Ratio (AVR) in retinal images2008
- An automatic system for the estimation of generalized arteriolar narrowing in retinal images2007
- Comparative study of retinal vessel segmentation methods on a new publicly available database2004
- Ridge-Based Vessel Segmentation in Color Images of the RetinaIEEE Transactions on Medical Imaging, 2004
- Revised formulas for summarizing retinal vessel diametersCurrent Eye Research, 2003
- Methods for evaluation of retinal microvascular abnormalities associated with hypertension/sclerosis in the atherosclerosis risk in communities study11The authors have no proprietary interest in the equipment and techniques described in this article.Ophthalmology, 1999
- An optimal algorithm for approximate nearest neighbor searching fixed dimensionsJournal of the ACM, 1998