Mitigation against overvoltages on a DC marine electrical system
Authors:
- 1 April 2009
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 420-427
Abstract
This paper analyzes the behavior of a highly capacitive DC marine network under fault conditions and demonstrates how overvoltages can be caused by the redistribution of stored energy following the clearance of a fault. This energy flow can be complex in nature, making it particularly difficult to sufficiently protect the network effectively. Through the analysis and simulation of a representative zonal DC marine network, this paper analyzes the causes and severity of overvoltages which can occur following a fault, identifying key contributing factors. The paper also demonstrates how the effects of a fault on the network can propagate, potentially causing damage to previously healthy parts of the network. Through this analysis, this paper identifies options for the mitigation of overvoltage transients in DC marine electrical systems.Keywords
This publication has 7 references indexed in Scilit:
- DC power system stability2009
- Overvoltage protection on a DC marine electrical system2008
- In system emulation (ISE) of a new current differential back-up protection relay2008
- Overcurrent Protection on Voltage-Source-Converter-Based Multiterminal DC Distribution SystemsIEEE Transactions on Power Delivery, 2006
- DC distribution for industrial systems: opportunities and challengesIEEE Transactions on Industry Applications, 2003
- The emitter turn-off thyristor-based DC circuit breaker2003
- Novel medium voltage fault current limiter based on polymer PTC resistorsIEEE Transactions on Power Delivery, 1999