An Experimental Evaluation of the APR1000 Core Flow Distribution Using a 1/5 Scale Model
Open Access
Abstract
The experimental data of core flow distribution are indispensable for obtaining licensing and facilitating the design of fluid systems of nuclear reactors. In this study, an Advanced power reactor Core flow and Pressure (ACOP) test facility was established to experimentally simulate the internal flow of the Advanced Power Reactor 1000 (APR1000) on a reduced length scale of 1/5. The core region was simulated by using 177 core simulators representing the fuel assemblies of the APR1000. The APR1000 flow distributions were synthetically identified by accurately measured parameters: the core inlet flow rate and outlet pressure under the four-pump balanced and unbalanced flow conditions. The overall inlet flow rates ranged from 87.7% to 112.0% relative to the averaged flow rate. Here, we scrutinize the flow distributions considering the flow conditions and internal structures and briefly describe the applied scaling method and design concept of the test facility.Keywords
Funding Information
- Korean Government (MOTIE, Ministry of Trade, Industry and Energy) (20217810100010)
This publication has 5 references indexed in Scilit:
- Experimental identification for flow distribution inside APR+ reactor vessel and direction of internal structure design improvementJournal of Nuclear Science and Technology, 2015
- Experimental study of the APR+ reactor core flow and pressure distributions under 4-pump running conditionsNuclear Engineering and Design, 2013
- A FLOW AND PRESSURE DISTRIBUTION OF APR+ REACTOR UNDER THE 4-PUMP RUNNING CONDITIONS WITH A BALANCED FLOW RATENuclear Engineering and Technology, 2012
- Thermal-Hydraulic R&Ds for the APR+ Developments in Korea2010