Asphericity of the anterior human cornea with different corneal diameters
Authors:
- José Manuel González-MéijomeJGJosé Manuel González-Méijome
- César Villa-CollarCVCésar Villa-Collar
- Robert Montés-MicóRMRobert Montés-Micó
- Antonio GomesAGAntonio Gomes
- 1 March 2007
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 33 (3) , 465-473
Abstract
To measure the anterior corneal asphericity (Q) with different corneal diameters. Department of Physics (Optometry), University of Minho, Braga, Portugal. Thirty-six eyes of 36 patients were evaluated using a videokeratoscope, and the Q-values were recorded. Topographic data were also analyzed using Vol-CT 6.89 software (Sarver & Associates, Inc) to obtain the Q-values with different corneal diameters (3.0 mm, 4.0 mm, 5.0 mm, 6.0 mm, and 7.0 mm). Variable Q models of corneal sagittal height were compared against models assuming constant Q-values obtained with the Medmont E300 videokeratoscope (Medmont Pty. Ltd.) and a standard Q model of -0.26. The peripheral rate of change in corneal Q with different corneal diameters increased as corneal astigmatism increased. As a result, differences in the sagittal height between the constant model and variable model were evident beyond the central 3.0 mm area. There were significant differences between low and high astigmatic corneas in Q-values measured by the Medmont along the flattest meridian (P = .004) and Q-values obtained with Vol-CT software with a 7.0 mm corneal diameter (P = .026). There were differences in sagittal corneal height calculations considering constant or variable models of Q. Concern arises when surgical interventions depend on corneal Q-values to predict the outcomes. Surgeons should be aware which procedure is behind Q computing by different corneal topographers and that a constant Q-value cannot reflect the actual shape of the cornea as significant departures from the actual sagittal height can arise depending on which Q-value is assumed.Keywords
This publication has 30 references indexed in Scilit:
- The Topography of the Central and Peripheral CorneaInvestigative Ophthalmology & Visual Science, 2006
- Wavefront-Guided versus Standard LASIK Enhancement for Residual Refractive ErrorsOphthalmology, 2006
- Differences between real and predicted corneal shapes after aspherical corneal ablationApplied Optics, 2005
- Corneal Asphericity and Apical Curvature in Children: A Cross-sectional and Longitudinal EvaluationInvestigative Ophthalmology & Visual Science, 2005
- A comparison of the ARK‐700A autokeratometer and Medmont E300 corneal topographer when measuring peripheral corneal curvatureOphthalmic and Physiological Optics, 2004
- Asfericidad corneal en una población de adultos jóvenes: Implicaciones clínicasArchivos de la Sociedad Española de Oftalmología, 2004
- Myopic versus hyperopic eyes: axial length, corneal shape and optical aberrationsJournal of Vision, 2004
- Descriptors of Corneal ShapeOptometry and Vision Science, 1998
- Corneal Eccentricity as a Tool for the Diagnosis of KeratoconusCornea, 1994
- Theoretical Eye Model with Aspherics*Journal of the Optical Society of America, 1971