Using Continuous Motion Monitoring Technology to Determine Patient’s Risk for Development of Pressure Ulcers
Authors:
- Eyal ZimlichmanEZEyal Zimlichman
- Zvika ShinarZSZvika Shinar
- Ronen RozenblumRRRonen Rozenblum
- Shiraz LevkovichSLShiraz Levkovich
- Sarit SkianoSSSarit Skiano
- Martine Szyper-KravitzMSMartine Szyper-Kravitz
- Arie AltmanAAArie Altman
- Howard AmitalHAHoward Amital
- Yehuda ShoenfeldYSYehuda Shoenfeld
- 1 December 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Patient Safety
- Vol. 7 (4) , 181-184
Abstract
To perform initial validation of a continuous motion monitoring technology that can potentially be used as a risk assessment tool to determine risk for developing pressure ulcers (PUs). We have used the EverOn system (Earlysense LTD, Ramat Gan, Israel) as a bed movement and activity monitor. The EverOn is a contactless continuous measurement system based on a piezoelectric sensor that is placed under the patient's mattress. The study was a noninterventional study performed in 2 medical departments in 2 medical centers. Recorded movement data from enrolled patients were retrospectively analyzed, and patients were assigned a motion level score. Motion scores for the first night of hospitalization were correlated with the Norton scale as calculated per patient on admission. Overall, 116 patients were included in the study from the 2 sites. Motion score was significantly different between the PU risk groups as determined by the Norton scale (10.7 ± 6.2 for low, 5.4 ± 4.9 for intermediate, and 1.6 ± 3.2 for high risk; P < 0.001). Using the Norton scale as a gold standard to define high risk for developing PU (≤14), the sensitivity of the motion score was 85%, and the specificity was 93%. With regard to individual risk components, we found that activity, mobility, physical condition, and incontinence correlated highly with motion level. The high correlation between the EverOn motion score and the calculated Norton scale indicates the potential of this technology to serve as a risk assessment tool for the development of PUs.Keywords
This publication has 10 references indexed in Scilit:
- Contactless respiratory and heart rate monitoring: validation of an innovative toolJournal of Medical Engineering & Technology, 2010
- Norton, Waterlow and Braden scores: a review of the literature and a comparison between the scores and clinical judgementJournal of Clinical Nursing, 2008
- Preventing Pressure Ulcers: The Goal Is ZeroThe Joint Commission Journal on Quality and Patient Safety, 2007
- Risk assessment scales for pressure ulcer prevention: a systematic reviewJournal of Advanced Nursing, 2006
- Pressure ulcers: validation of two risk assessment scalesJournal of Clinical Nursing, 2005
- The effect of various combinations of turning and pressure reducing devices on the incidence of pressure ulcersInternational Journal of Nursing Studies, 2005
- The cost of pressure ulcers in the UKAge and Ageing, 2004
- Pressure Ulcer Prevention and ManagementJAMA, 2003
- Contribution of Individual Items to the Performance of the Norton Pressure Ulcer Prediction ScaleJournal of the American Geriatrics Society, 1998
- A Conceptual Schema for the Study of the Etiology of Pressure SoresRehabilitation Nursing Journal, 1987