The Development of a Novel Headspace O2 Concentration Measurement Sensor for Vials
Open Access
Abstract
In the process of manufacture and transportation, vials are prone to breakage and cracks. Oxygen (O2) in the air entering vials can lead to the deterioration of medicine and a reduction in pesticide effects, threatening the life of patients. Therefore, accurate measurement of the headspace O2 concentration for vials is crucial to ensure pharmaceutical quality. In this invited paper, a novel headspace oxygen concentration measurement (HOCM) sensor for vials was developed based on tunable diode laser absorption spectroscopy (TDLAS). First, a long–optical–path multi–pass cell was designed by optimizing the original system. Moreover, vials with different O2 concentrations (0%, 5%, 10%, 15%, 20%, and 25%) were measured with this optimized system in order to study the relationship between the leakage coefficient and O2 concentration; the root mean square error of the fitting was 0.13. Moreover, the measurement accuracy indicates that the novel HOCM sensor achieved an average percentage error of 1.9%. Sealed vials with different leakage holes (4, 6, 8, and 10 mm) were prepared to investigate the variation in the headspace O2 concentration with time. The results show that the novel HOCM sensor is non-invasive and has a fast response and high accuracy, with prospects in applications for online quality supervision and management of production lines.Keywords
Funding Information
- National Natural Science Foundation of China (51676130, 20ZR1438900)
- Natural Science Foundation of Shanghai Municipality (51676130, 20ZR1438900)
This publication has 35 references indexed in Scilit:
- Evaluation of a Non‐destructive High‐voltage Technique for the Detection of Pinhole Leaks in Flexible and Semi‐rigid Packages for FoodsPackaging Technology and Science, 2013
- CW DFB RT diode laser-based sensor for trace-gas detection of ethane using a novel compact multipass gas absorption cellApplied Physics B, 2013
- Non-intrusive headspace gas measurements by laser spectroscopy – Performance validation by a reference sensorJournal of Food Engineering, 2012
- Effects of Subzero Temperature Exposure and Supercooling on Glass Vial Breakage: Risk Management and Other Applications in Cold Chain DistributionPDA Journal of Pharmaceutical Science and Technology, 2012
- Vacuum Decay Container Closure Integrity Leak Test Method Development and Validation for a Lyophilized Product-Package SystemPDA Journal of Pharmaceutical Science and Technology, 2011
- Very long optical path-length from a compact multi-pass cellApplied Physics B, 2010
- Factors Affecting the Chemical Durability of Glass Used in the Pharmaceutical IndustryAAPS PharmSciTech, 2010
- Infrared Spectroscopy on Smoke Produced by Cauterization of Animal TissueSensors, 2010
- Vial breakage during freeze‐drying: Crystallization of sodium chloride in sodium chloride‐sucrose frozen aqueous solutionsJournal of Pharmaceutical Sciences, 2007
- Approach to optical interference fringes reduction in diode laser absorption spectroscopyApplied Physics B, 2007