18F-FDG PET/CT of Patients With Cancer: Comparison of Whole-Body and Limited Whole-Body Technique
- 1 December 2010
- journal article
- research article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 195 (6) , 1397-1403
Abstract
OBJECTIVE. Use of the routine field of view for whole-body 18F-FDG PET/CT can lead to underestimation of the true extent of the disease because metastasis outside the typical base of skull to upper thigh field of view can be missed. The purpose of this study was to evaluate the incremental added value of true whole-body as opposed to this limited whole-body PET/CT of cancer patients. MATERIALS AND METHODS. True whole-body FDG PET/CT, from the top of the skull to the bottom of the feet, was performed on 500 consecutively registered patients. A log was kept of cases of suspected malignancy outside the typical limited whole-body field of view. Suspected lesions in the brain, skull, and extremities were verified by correlation with surgical pathologic or clinical follow-up findings. RESULTS. Fifty-nine of 500 patients had PET/CT findings suggestive of malignancy outside the limited whole-body field of view. Thirty-one of those patients had known or suspected malignancy outside the limited whole-body field of view at the time of the true whole-body study. Among the other 28 patients, follow-up data were not available for two, six had false-positive findings, and new cancerous involvement was confirmed in 20. Detection of malignancy outside the limited whole-body field of view resulted in a change in management in 65% and in staging in 55% of the 20 cases. CONCLUSION. Our study showed that 20 of 500 (4.0%) of patients had previously unsuspected malignancy outside the typical limited whole-body field of view. Detection of such malignancy resulted in a change in management in 13 of 500 cases (2.6%). We propose that adopting a true whole-body field of view in the imaging of cancer patients may lead to more accurate staging and restaging than achieved with the routinely used limited whole-body field of view.Keywords
This publication has 15 references indexed in Scilit:
- Multimodality imaging: an update on PET/CT technologyEuropean Journal of Nuclear Medicine and Molecular Imaging, 2008
- Prevalence and patterns of soft tissue metastasis: detection with true whole-body F-18 FDG PET/CTBMC Medical Imaging, 2007
- Clinical value of including the head and lower extremities in 18F-FDG PET/CT imaging for patients with malignant melanomaNuclear Medicine Communications, 2007
- Integrated PET/CT: Current Applications and Future DirectionsRadiology, 2006
- Accuracy of Whole-Body Dual-Modality Fluorine-18–2-Fluoro-2-Deoxy-d-Glucose Positron Emission Tomography and Computed Tomography (FDG-PET/CT) for Tumor Staging in Solid Tumors: Comparison With CT and PETJournal of Clinical Oncology, 2004
- Does Whole-Body 2-[ 18 F]-Fluoro-2-Deoxy-D-Glucose Positron Emission Tomography Have an Advantage Over Thoracic Positron Emission Tomography for Staging Patients With Lung Cancer?Chest, 2004
- Whole-Body Dual-Modality PET/CT and Whole-Body MRI for Tumor Staging in OncologyJAMA, 2003
- Positron Emission Tomography Scanning: Current and Future ApplicationsAnnual Review of Medicine, 2002
- Combining anatomy and function: the path to true image fusionEuropean Radiology, 2001
- A row-action alternative to the EM algorithm for maximizing likelihood in emission tomographyIEEE Transactions on Medical Imaging, 1996