Compact monochromatic flash x‐ray generator utilizing a disk‐cathode molybdenum tube

Authors:

Abstract
The high‐voltage condensers in a polarity‐inversion two‐stage Marx surge generator are charged from −50 to −70 kV by a power supply, and the electric charges in the condensers are discharged to an x‐ray tube after closing gap switches in the surge generator with a trigger device. The x‐ray tube is a demountable diode, and the turbo molecular pump evacuates air from the tube with a pressure of approximately 1 mPa. Clean molybdenum lines are produced using a 20 μm‐thick zirconium filter, since the tube utilizes a disk cathode and a rod target, and bremsstrahlung rays are not emitted in the opposite direction to that of electron acceleration. At a charging voltage of −70 kV, the instantaneous tube voltage and current were 120 kV and 1.0 kA, respectively. The x‐ray pulse widths were approximately 70 ns, and the generator produced instantaneous number of photons was approximately per pulse at 0.5 m from the source of 3.0 mm in diameter.

This publication has 12 references indexed in Scilit: