Transjugular closure of a large patent ductus arteriosus in a 1100-g infant
Authors:
- 11 May 2026
- journal article
- case report
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 36 (4) , 854-856
Abstract
The patent ductus arteriosus is the most common cardiac anomaly in neonates. Haemodynamically significant patent ductus arteriosus is associated with increased morbidity and mortality in preterm babies. Transfemoral venous access is the standard route for patent ductus arteriosus device closure, even in very low birth weight infants. The transjugular approach is also an alternative, but it is more challenging, especially in preterm infants. We report a successful transjugular closure of a patent ductus arteriosus in a 1100‑g infant (the smallest worldwide), where transfemoral access was not possible due to bilateral iliofemoral venous thrombosis.Keywords
This publication has 8 references indexed in Scilit:
- The Transcatheter Closure of Patent Ductus Arteriosus in Extremely Low-Birth-Weight Infants: Technique and ResultsJournal of Cardiovascular Development and Disease, 2023
- Transjugular venous approach for Piccolo patent ductus arteriosus closure in a 1.4 kg infantCardiology in the Young, 2021
- Transcatheter closure of a large patent ductus arteriosus using jugular access in an infantJournal of Thoracic Disease, 2018
- Transcatheter closure of patent ductus arteriosus: Past, present and futureArchives of Cardiovascular Diseases, 2014
- Transcatheter closure of moderate to large patent ductus arteriosus with the Amplatzer duct occluderCatheterization and Cardiovascular Interventions, 2007
- Severity of the ductal shunt: a comparison of different markersArchives of Disease in Childhood - Fetal and Neonatal Edition, 2005
- Neonatal symptomatic thromboembolism in Germany: two year surveyArchives of Disease in Childhood - Fetal and Neonatal Edition, 1997
- Congenital Heart Disease in 56,109 Births Incidence and Natural HistoryCirculation, 1971