Implementation of EPID transit dosimetry based on a through-air dosimetry algorithm
Authors:
- 12 December 2011
- journal article
- Published by Wiley in Medical Physics
- Vol. 39 (1) , 87-98
Abstract
Purpose: A method to perform transit dosimetry with an electronic portal imaging device(EPID) by extending the commercial implementation of a published through-air portal doseimage (PDI) prediction algorithm Van Eschet al. [Radiother. Oncol. 71, 223–234 (2004)] is proposed and validated. A detailed characterization of the attenuation, scattering, and EPID response behind objects in the beam path is used to convert through-air PDIs into transit PDIs. Methods: The EPIDdetector response beyond a range of water equivalent thicknesses (0–35 cm) and field sizes (3×3 to 22.2×29.6 cm2) was analyzed. A constant air gap between the phantom exit surface and the EPID was utilized. A model was constructed that accounts for the beam’s attenuation along the central axis, the presence of phantom scattered radiation, the detector’s energy dependent response, and the difference in EPID off-axis pixel response relative to the central pixel. The efficacy of the algorithm was verified by comparing predicted and measured PDIs for IMRT fields delivered through phantoms of increasing complexity. Results: The expression that converts a through-air PDI to a transit PDI is dependent on the object’s thickness, the irradiated field size, and the EPID pixel position. Monte Carlo derived narrow-beam linear attenuation coefficients are used to model the decrease in primary fluence incident upon the EPID due to the object’s presence in the beam. This term is multiplied by a factor that accounts for the broad beam scatter geometry of the linac-phantom-EPID system and the detector’s response to the incident beam quality. A 2D Gaussian function that models the nonuniformity of pixel response across the EPIDdetector plane is developed. For algorithmic verification, 49 IMRT fields were repeatedly delivered to homogeneous slab phantoms in 5 cm increments. Over the entire set of measurements, the average area passing a 3%/3mm gamma criteria slowly decreased from 98% for no material in the beam to 96.7% for 35 cm of material in the beam. The same 49 fields were delivered to a heterogeneous slab phantom and on average, 97.1% of the pixels passed the gamma criteria. Finally, a total of 33 IMRT fields were delivered to the anthropomorphic phantom and on average, 98.1% of the pixels passed. The likelihood of good matches was independent of anatomical site. Conclusions: A prediction of the transit PDI behind a phantom or patient can be created for the purposes of treatment verification via an extension of the Van Esch through-air PDI algorithm. The results of the verification measurements through phantoms indicate that further investigation through patients during their treatments is warranted.Keywords
This publication has 35 references indexed in Scilit:
- Radiation Oncology Safety Information System (ROSIS) – Profiles of participants and the first 1074 incident reportsRadiotherapy and Oncology, 2010
- A literature review of electronic portal imaging for radiotherapy dosimetryRadiotherapy and Oncology, 2008
- Establishing action levels for EPID‐based QA for IMRTJournal of Applied Clinical Medical Physics, 2008
- Monte Carlo modelling of a‐Si EPID response: The effect of spectral variations with field size and positionMedical Physics, 2006
- Monte Carlo computation of dosimetric amorphous silicon electronic portal imagesMedical Physics, 2004
- The use of an aSi-based EPID for routine absolute dosimetric pre-treatment verification of dynamic IMRT fieldsRadiotherapy and Oncology, 2004
- Guidance document on delivery, treatment planning, and clinical implementation of IMRT: Report of the IMRT subcommittee of the AAPM radiation therapy committeeMedical Physics, 2003
- An investigation of a new amorphous silicon electronic portal imaging device for transit dosimetryMedical Physics, 2002
- Dosimetric investigation and portal dose image prediction using an amorphous silicon electronic portal imaging deviceMedical Physics, 2001
- Monte Carlo studies of the exit photon spectra and dose to a metal/phosphor portal imaging screenMedical Physics, 2000