Abstract
This study proposes a method to detect and quantify broken rotor bar fault using zero‐sequence voltage in a wye‐connected squirrel‐cage induction motor. The zero‐sequence voltage is analysed and two fault severity factors are defined. The factors are almost independent of motor speed and load torque. Furthermore, it is proved that closed‐loop control has little influence on the diagnosis results. Consequently, the method can detect broken rotor bar fault for induction motors in both open‐ and closed‐loop drives. Moreover, the method can discriminate the broken bar fault from a low‐frequency load oscillation, even when these two phenomena occur simultaneously. In addition, the influence of unbalanced voltage supply on the diagnosis results is negligible. The effectiveness and robustness of the proposed method have been validated by experimental results.Keywords
Funding Information
- National Natural Science Foundation of China (51690182)
This publication has 43 references indexed in Scilit:
- Quantitative broken rotor bar fault detection for closed‐loop controlled induction motorsIET Electric Power Applications, 2016
- Application of intelligent tools to detect and classify broken rotor bars in three‐phase induction motors fed by an inverterIET Electric Power Applications, 2016
- A survey on time and frequency characteristics of induction motors with broken rotor bars in line-start and inverter-fed modesMechanical Systems and Signal Processing, 2015
- Advances in Electrical Machine, Power Electronic, and Drive Condition Monitoring and Fault Detection: State of the ArtIEEE Transactions on Industrial Electronics, 2014
- EMD-Based Analysis of Industrial Induction Motors With Broken Rotor Bars for Identification of Operating Point at Different Supply ModesIEEE Transactions on Industrial Informatics, 2013
- Condition monitoring and diagnosis of rotor faults in induction machines: State of art and future perspectives2013
- Locating Broken Bars in Line-Start and Inverter-Fed Induction Motors Using Modified Winding Function MethodElectromagnetics, 2012
- A Simple Real-Time Fault Signature Monitoring Tool for Motor-Drive-Embedded Fault Diagnosis SystemsIEEE Transactions on Industrial Electronics, 2010
- Review of condition monitoring of rotating electrical machinesIET Electric Power Applications, 2008
- Condition Monitoring and Fault Diagnosis of Electrical Motors—A ReviewIEEE Transactions on Energy Conversion, 2005