Abstract
Background: This study aims to identify pararenal aortic diameter changes following endovascular aortic repair and to investigate the effects of suprarenal fixation on renal function. Methods: Between May 2006 and January 2019, a total of 168 patients (135 males, 33 females; mean age: 75.2±8.4 years; range, 48 to 93 years) who underwent endovascular aortic repair were retrospectively analyzed. To compare the effects of graft types, we measured the change in pararenal aortic diameter at four levels: below the celiac artery, below the superior mesenteric artery, at the lowest renal artery, and 1 cm below the lowest renal artery. To evaluate the effect of suprarenal fixation on renal function, serial measurements of serum creatinine, glomerular filtration rate, creatinine clearance rate, and estimated glomerular filtration rate were made. We examined the factors related to post-procedural aortic diameter. Results: The mean change in the aortic diameter was statistically significant, being 12.9±10% in the suprarenal fixation group and 6.19±6.9% in the infrarenal fixation group only at the lowest renal artery level (p=0.001). There was no significant difference in the rate of type I endoleak (p=0.330) or renal function and adverse events (p>0.107) between the groups. The formula for calculating post-procedural aortic diameter was as follows: post-procedural aortic diameter (renal artery level, mm) =1.845 (in case of suprarenal fixation) + 1.012 × pre-procedural aortic diameter (renal artery level, mm) + 0.029 × follow-up time (months) + 0.039 × oversizing (%) (R2=0.773, pConclusion: Suprarenal fixation affects the infrarenal aortic diameter at the lowest renal artery level without significant type I endoleak. However, it does not result in significant renal dysfunction. Pre-procedural aortic diameter, computed tomography follow-up time, suprarenal fixation type, and stent oversizing are the only definite independent correlation factors for postprocedural aortic diameter. This formula can predict the change of aortic diameter after endovascular aortic repair.Keywords
This publication has 17 references indexed in Scilit:
- Suprarenal graft fixation in endovascular abdominal aortic aneurysm repair is associated with a decrease in renal functionJournal of Vascular Surgery, 2012
- Endografts with suprarenal fixation do not perform better than those with infrarenal fixation in the treatment of patients with short straight proximal aortic necksJournal of Vascular Surgery, 2012
- Long-term follow-up of neck expansion after endovascular aortic aneurysm repairJournal of Vascular Surgery, 2010
- Outcomes following endovascular abdominal aortic aneurysm repair (EVAR): An anatomic and device-specific analysisJournal of Vascular Surgery, 2008
- Do Abdominal Aortic Aneurysm Necks Increase in Size Faster after Endovascular than Open Repair?European Journal of Vascular and Endovascular Surgery, 2008
- Device-specific aneurysm sac morphology after endovascular aneurysm repair: Evaluation of contemporary graft materialsJournal of Vascular Surgery, 2008
- Mid- and long-term device migration after endovascular abdominal aortic aneurysm repair: A comparison of AneuRx and Zenith endograftsJournal of Vascular Surgery, 2005
- Influence of endograft oversizing on device migration, endoleak, aneurysm shrinkage, and aortic neck dilation: results from the zenith multicenter trialJournal of Vascular Surgery, 2004
- Evaluation of the proximal aortic neck enlargement following endovascular repair of abdominal aortic aneurysm: 3-years experienceEuropean Radiology, 2003
- Reporting standards for endovascular aortic aneurysm repairJournal of Vascular Surgery, 2002