Shrink-Induced Microelectrode Arrays for Trace Mercury Ions Detection
- 21 December 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (7) , 2435-2441
Abstract
An ultrasensitive microelectrode arrays (MEA) mercury sensor based on heat-shrinkable polymer was fabricated by a very simple and low-cost method for the first time. We sputter comb-finger gold electrode on the heat-shrinkable polymer, made use of heat shrinkage and sticky characteristics of the polymer to construct MEA, and then detected trace mercury ions (Hg2+) in the water by anodic stripping voltammetry (ASV). The characterization result indicated that the shrink polymer prepared by different heating temperature had controllable shrinkage ratios, and the electrode surface presented unique wrinkle structure by heating process. Due to the non-linear diffusion characteristic of the micro electrode and the micro-wrinkle structure, performance of the sensor had been improved greatly. The signal-to-noise ratio (Faraday current divide Background current) increased notably, and the sensor’s detection limit was achieved as 0.0874 ppb. This is a very effective way to detect ultra-low concentrations mercury ions and the heat-shrinkable film-based microelectrode arrays construction method can be applied to many fields.Keywords
This publication has 27 references indexed in Scilit:
- Disposable screen-printed sensors modified with bismuth precursor compounds for the rapid voltammetric screening of trace Pb(II) and Cd(II)Analytica Chimica Acta, 2012
- Determination of Lead and Cadmium in Sea‐ and Freshwater by Anodic Stripping Voltammetry with a Vibrating Bismuth ElectrodeElectroanalysis, 2010
- Microfabricated on-chip integrated Au–Ag–Au three-electrode system for in situ mercury ion determinationThe Analyst, 2010
- Novel disposable microfabricated antimony-film electrodes for adsorptive stripping analysis of trace Ni(II)Electrochemistry Communications, 2009
- Determination of Mercury by Anodic Stripping Voltammetry with a Gold Nanoparticle‐Modified Glassy Carbon ElectrodeElectroanalysis, 2007
- Low dose mercury toxicity and human healthEnvironmental Toxicology and Pharmacology, 2005
- Quantitative determination of zinc in milkvetch by anodic stripping voltammetry with bismuth film electrodesTalanta, 2005
- Nanoelectrodes, nanoelectrode arrays and their applicationsThe Analyst, 2004
- Method to reduce the memory effect of mercury in the analysis of fish tissue using inductively coupled plasma mass spectrometryAnalytica Chimica Acta, 2004
- Microfabricated Array of Iridium Microdisks as a Substrate for Direct Determination of Cu2+or Hg2+Using Square-Wave Anodic Stripping VoltammetryAnalytical Chemistry, 1999