Conventionally ligated versus self-ligating metal brackets--a comparative study
Open Access
- 21 November 2008
- journal article
- research article
- Published by Oxford University Press (OUP) in European Journal of Orthodontics
- Vol. 30 (6) , 654-660
Abstract
The purpose of this study was to compare the frictional properties of four self-ligating metal brackets, Speed, Damon 2, In-Ovation, and Time, with those of three conventionally ligated metal brackets, Time, Victory Twin, and Discovery. The self-ligating Time bracket can also be used as a conventionally ligated bracket. Friction was tested 20 times for each bracket/wire combination using a Zwick testing machine with stainless steel wires in three different wire dimensions (0.017 × 0.025, 0.018 × 0.025, and 0.019 × 0.025 inches). All brackets had a 0.022 inch slot and the prescription of an upper first premolar. The data were statistically analysed with unsigned comparisons of all bracket/wire combinations using the Mann–Whitney U-test and the Games–Howell post hoc test. The results showed almost all brackets to have the lowest frictional force with a wire dimension of 0.018 × 0.025 inch. Friction of the self-ligating brackets using wire with a dimension of 0.018 × 0.025 inches was 45–48 per cent lower than with 0.017 × 0.025 and 0.019 × 0.025 inch wires. Friction of the conventionally ligated brackets showed a 14 per cent or less reduced friction with 0.018 × 0.025 inch wire compared with 0.017 × 0.025 and 0.019 × 0.025 inch wires. The self-ligating metal brackets showed lower frictional forces with a 0.018 × 0.025 inch wire than conventionally ligated brackets, whereas conventionally ligated brackets showed lower friction with 0.017 × 0.025 and 0.019 × 0.025 inch wire. Friction values vary with different bracket/archwire combinations and, therefore, the choice of a bracket system for treatment should consider the correct wire dimension to produce the lowest possible frictional forces.Keywords
This publication has 20 references indexed in Scilit:
- The Effect of Artificial Saliva on the Frictional Forces between Orthodontic Brackets and ArchwiresBritish Journal of Orthodontics, 1995
- An experimental apparatus for the simulation of three-dimensional movements in orthodonticsJournal of Biomedical Engineering, 1992
- A comparative study of frictional forces between orthodontic brackets and arch wiresAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1991
- Effect of bracket and wire composition on frictional forcesEuropean Journal of Orthodontics, 1991
- Application of the orthodontic measurement and simulation system (OMSS) in orthodonticsEuropean Journal of Orthodontics, 1991
- Evaluation of friction between ceramic brackets and orthodontic wires of four alloysAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1990
- Frictional forces between bracket and arch wireAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1989
- Frictional changes in force values caused by saliva substitutionAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1987
- A comparative study of frictional resistances between orthodontic bracket and arch wireAmerican Journal of Orthodontics, 1980
- Evaluation of friction forces in the 0·022 × 0·028 edgewise bracket in vitroJournal of Biomechanics, 1970