Nerve repair by means of vein filled with muscle grafts I. Clinical results
Authors:
- Pierluigi TosPTPierluigi Tos
- Timothy R. CushwayTCTimothy R. Cushway
- Stefano GeunaStefano Geuna
- 3 January 2000
- journal article
- research article
- Published by Wiley in Microsurgery
- Vol. 20 (1) , 32-36
Abstract
Peripheral nerve lesions with a long segment defect need a grafting conduit to heal. Although autogenous nerve grafting is still considered the best method for bridging nerve defects, several alternative types of conduits (biological and synthetic) have been studied. We have demonstrated in previous experimental research in rats that a graft made using a vein (providing a guide for nerve regeneration) filled with fresh skeletal muscle (to prevent vein collapse and support axon regeneration) gave similar results to traditional nerve grafts. On this basis, we decided to use the muscle‐vein‐combined grafts in clinical cases. From 1993 to 1997, this technique was applied for bridging both sensory and mixed nerve defects (21 cases). We report good results in 85% of our cases with a minimum follow‐up of 14 months. These results, obtained on nerve defects ranging from 0.5 to 6 cm in length, seem to be superior to those reported with other kinds of artificial or biological conduits. © 2000 Wiley‐Liss, Inc. MICROSURGERY 20:32–36 2000Keywords
This publication has 20 references indexed in Scilit:
- Peripheral nerve regeneration through nerve guides seeded with adult Schwann cellsNeuropathology and Applied Neurobiology, 1997
- Nerve-Muscle Sandwich Grafts: the Importance of Schwann Cells in Peripheral Nerve Regeneration through Muscle Basal Lamina ConduitsJournal of Hand Surgery (European Volume), 1995
- Increased axonal regeneration over long nerve gaps using autologous nerve‐muscle sandwich graftsMicrosurgery, 1995
- Trophism, Tropism and Specificity in Nerve RegenerationJournal of Reconstructive Microsurgery, 1994
- A Prospective Clinical Evaluation of Autogenous Vein Grafts Used as a Nerve Conduit for Distal Sensory Nerve Defects of 3 cm or LessPlastic and Reconstructive Surgery, 1990
- Clinical Nerve Reconstruction with a Bioabsorbable Polyglycolic Acid TubePlastic and Reconstructive Surgery, 1990
- Basic fibroblast growth factor released from synthetic guidance channels facilitates peripheral nerve regeneration across long nerve gapsJournal of Neuroscience Research, 1989
- Chemotactic Arrangement of Axons Inside and Distal to a Venous GraftJournal of Reconstructive Microsurgery, 1987
- Experimental study of bridging the peripheral nerve gap with skeletal muscleMicrosurgery, 1986
- Reorganization and orientation of regenerating nerve fibres, perineurium, and epineurium in preformed mesothelial tubes – an experimental study on the sciatic nerve of ratsJournal of Neuroscience Research, 1981