Whirling technique for thyroid fine needle aspiration biopsy: a preliminary study of effectiveness and safety
Open Access
- 1 January 2021
- journal article
- research article
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 40 (1) , 147-157
Abstract
This study was aimed to compare thyroid fine needle aspiration biopsy (FNAB) techniques (conventional vs. whirling) in terms of cell harvesting ability ex vivo, the unsatisfactory rate and complication rate in vivo, and multi-operator performance in a phantom study. In the ex vivo study, cell counts per background at ×100 magnification were compared between both techniques. In the in vivo study, 70 patients who underwent whirling FNAB from July 2019 to November 2019 were retrospectively compared to 140 matched patients who underwent conventional FNAB from January 2018 to November 2019 regarding the unsatisfactory rate and complication rate. As a subgroup analysis, thyroid nodules in difficult biopsy situations (nodule diameter <10 mm and location within 3 mm from major anatomical structures) were compared. In the phantom study, eight operators with varying experience recorded levels of dexterity and needle tip visualization, and their preferences for both techniques. In the ex vivo study, cell counts were comparable between both techniques in all thyroid nodule mimickers (80.0% vs. 87.5%, P=0.178). In the in vivo study, the unsatisfactory rate was comparable between the two groups (15.7% vs. 12.9%, P=0.859). In the subgroup analysis, the whirling technique demonstrated a lower unsatisfactory rate (5.9% vs. 24.2%, P=0.045) and a lower complication rate (0% vs. 6.1%, P=0.553). In the phantom study, the whirling technique demonstrated better dexterity and needle tip visualization and was preferred by all operators. This newly proposed whirling technique for thyroid FNAB may be effective and safe, especially in difficult biopsy situations.Keywords
This publication has 27 references indexed in Scilit:
- Role of ultrasound‐guided core‐needle biopsy in the assessment of head and neck lesions: A meta‐analysis and systematic review of the literatureHead & Neck, 2011
- Ultrasonography and the Ultrasound-Based Management of Thyroid Nodules: Consensus Statement and RecommendationsKorean Journal of Radiology, 2011
- Quality Improvement Guidelines for Percutaneous Transhepatic Cholangiography, Biliary Drainage, and Percutaneous CholecystostomyJournal of Vascular and Interventional Radiology, 2010
- Clinical complications following thyroid fine‐needle biopsy: a systematic reviewClinical Endocrinology, 2009
- Very high prevalence of thyroid nodules detected by high frequency (13 MHz) ultrasound examinationEuropean Journal of Clinical Investigation, 2009
- Techniques for thyroid FNA: A synopsis of the National Cancer Institute Thyroid Fine‐Needle Aspiration State of the Science ConferenceDiagnostic Cytopathology, 2008
- Fine-Needle Aspiration of the Thyroid: Technique and TerminologyEndocrinology and Metabolism Clinics of North America, 2007
- Sonographically guided fine-needle biopsy of thyroid nodules: the effects of nodule characteristics, sampling technique, and needle size on the adequacy of cytological materialClinical Radiology, 2007
- Sonography and Sonographically Guided Fine-Needle Aspiration Biopsy of the Thyroid Gland: Indications and Techniques, Pearls and PitfallsAmerican Journal of Roentgenology, 2003
- Efficacy of Ultrasound-Guided Fine-Needle Aspiration Biopsy in the Diagnosis of Complex Thyroid NodulesThe Journal of Clinical Endocrinology & Metabolism, 2001