Evaluation of a new PVC-free catheter material for intermittent catheterization: A prospective, randomized, crossover study
Authors:
- Kerstin JohanssonKJKerstin Johansson
- Gunvor GreisGGGunvor Greis
- Birgit JohanssonBJBirgit Johansson
- Agneta GrundtmannAGAgneta Grundtmann
- Yvonne PahlbyYPYvonne Pahlby
- Solveig TörnSTSolveig Törn
- Hanna AxelbergHAHanna Axelberg
- Petrea CarlssonPCPetrea Carlsson
Open Access
- 5 July 2012
- journal article
- research article
- Published by Taylor & Francis in Scandinavian Journal of Urology
- Vol. 47 (1) , 33-37
Abstract
Objective. Polyvinyl chloride (PVC) is commonly used as a catheter material in catheters for clean intermittent catheterization (CIC) but, owing mainly to environmental concerns, a PVC-free material has been proposed. The objective of this study was to compare patients' tolerability for catheters made of PVC and a newly developed PVC-free material. Material and methods. This was a prospective, randomized, crossover study in 104 male patients with maintained urethra sensibility who practised CIC. The patients evaluated in a randomized order a PVC and a PVC-free LoFric® catheter after 1 week's use of each. The material properties and tolerability, i.e. reported perceived discomfort, of each catheter were compared and adverse events documented. Results. Twenty-nine (28%) and 15 (14%) patients reported discomfort when using the PVC catheter and the PVC-free LoFric catheter, respectively. A comparison showed that five patients (5%) reported discomfort with the PVC-free and not with the PVC catheter, and 19 patients (18%) reported discomfort with the PVC and not with the PVC-free catheter (p = 0.0066). Forty patients reported a total of 91 adverse events, of which the most common were discomfort in terms of pain, a burning sensation and bleeding. Conclusions. Generally low discomfort rates were reported in the study population, suggesting a high tolerance for CIC with catheters of both the PVC and the PVC-free materials. The lowest discomfort was, however, found when CIC was performed using the PVC-free LoFric catheter.Keywords
This publication has 16 references indexed in Scilit:
- Safety of a new compact catheter for men with neurogenic bladder dysfunction: a randomised, crossover and open-labelled studySpinal Cord, 2011
- Renal Failure Secondary to Transurethral Resection of Bladder Tumors at the Ureteric Orifice: A Serious, Poorly Known ComplicationUroToday International Journal, 2011
- A Multicenter, Double-Blind, Randomized, Parallel Group Study Comparing Polyvinyl Chloride and Polyvinyl Chloride-Free Catheter MaterialsJournal of Urology, 2009
- Development and environmental improvements of plastics for hydrophilic catheters in medical care: an environmental evaluationJournal of Cleaner Production, 2008
- A Prospective Randomized Trial Of The Lofric Hydrophilic Coated Catheter Versus Conventional Plastic Catheter For Clean Intermittent CatheterizationJournal of Urology, 2003
- Conservative management in neurogenic bladder dysfunctionCurrent Opinion in Urology, 2002
- Clean Intermittent Catheterization in Boys Using the Lofric CatheterJournal of Urology, 1996
- Clean Intermittent Catheterization in Spinal Cord Injury Patients: Long-Term Followup of a Hydrophilic Low Friction TechniqueJournal of Urology, 1995
- Patient Satisfaction and the Lofric Catheter for Clean Intermittent CatheterizationJournal of Urology, 1995
- Urethral cytology in spinal cord injury patients performing intermittent catheterisationSpinal Cord, 1994