Effective hemodynamic monitoring
Top Cited Papers
Open Access
- 28 September 2022
- journal article
- review article
- Published by Springer Nature in Critical Care
- Vol. 26 (1) , 1-10
Abstract
Hemodynamic monitoring is the centerpiece of patient monitoring in acute care settings. Its effectiveness in terms of improved patient outcomes is difficult to quantify. This review focused on effectiveness of monitoring-linked resuscitation strategies from: (1) process-specific monitoring that allows for non-specific prevention of new onset cardiovascular insufficiency (CVI) in perioperative care. Such goal-directed therapy is associated with decreased perioperative complications and length of stay in high-risk surgery patients. (2) Patient-specific personalized resuscitation approaches for CVI. These approaches including dynamic measures to define volume responsiveness and vasomotor tone, limiting less fluid administration and vasopressor duration, reduced length of care. (3) Hemodynamic monitoring to predict future CVI using machine learning approaches. These approaches presently focus on predicting hypotension. Future clinical trials assessing hemodynamic monitoring need to focus on process-specific monitoring based on modifying therapeutic interventions known to improve patient-centered outcomes.Keywords
Funding Information
- NHLBI (HL141916)
This publication has 111 references indexed in Scilit:
- Perioperative increase in global blood flow to explicit defined goals and outcomes after surgery: a Cochrane Systematic ReviewBritish Journal of Anaesthesia, 2013
- The holistic view on perfusion monitoring in septic shockCurrent Opinion in Critical Care, 2012
- Fluid management in critically ill patients: the role of extravascular lung water, abdominal hypertension, capillary leak, and fluid balanceAnnals of Intensive Care, 2012
- Defining the boundaries of bedside pulse contour analysis: dynamic arterial elastanceCritical Care, 2011
- Dynamic arterial elastance to predict arterial pressure response to volume loading in preload-dependent patientsCritical Care, 2011
- SvO2 to monitor resuscitation of septic patients: let's just understand the basic physiologyCritical Care, 2011
- Cardiorespiratory instability before and after implementing an integrated monitoring system*Critical Care Medicine, 2011
- Oesophageal DopplerCurrent Opinion in Critical Care, 2009
- Detecting volume responsiveness and unresponsiveness in intensive care unit patients: two different problems, only one solutionCritical Care, 2009
- Randomized Evaluation of Pulse Oximetry in 20,802 Patients; IIAnesthesiology, 1993