Evaluation of a device to detect neonatal hypothermia in a clinical setting in Ghana
Open Access
- 24 October 2023
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS Global Public Health
- Vol. 3 (10) , e0001681
Abstract
Neonatal hypothermia poses an increased risk of infection, hypoglycemia, metabolic dysfunction, and mortality, particularly in preterm or low birthweight (LBW) infants. However, early detection of hypothermia and prompt thermoregulation can mitigate these effects thus, the need for continuous neonatal temperature monitoring. The BEMPU TempWatch is a small bracelet designed for continuous temperature monitoring for neonates. When the body temperature falls below 36.5˚C, the bracelet generates an alarm sound and flashes an orange light, indicating hypothermia. This study aimed to assess the validity of the BEMPU TempWatch in detecting hypothermia in a clinical setting in Ghana using sensitivity and specificity. Additionally, the study sought to identify factors associated with misclassification using logistic regression analysis. A standardized questionnaire collected information about the mother, pregnancy, delivery, and neonate. The BEMPU TempWatch was placed on the wrist of the neonate, and over a 24-hour follow-up period, a nurse took 4-hourly axillary temperature readings using a digital thermometer. Whenever the device’s alarm sounded, a nurse immediately checked and recorded the axillary temperature, undertook necessary clinical actions, and rechecked after 30 minutes. Among the 249 neonates included in the study, 57.0% were female, 12.5% were extremely LBW, and 13.7% were extremely preterm. Based on 1,973 temperature readings, the sensitivity of the BEMPU TempWatch in detecting hypothermia was 67.8%, and the specificity was 95.9%. The sensitivity was lower among neonates being treated in incubators (58.4%) compared to those not (82.7%). Sensitivity was higher among neonates with LBW (1,500–2,500g) (73.5%) than very or extremely LBW neonates (<1,500g) (62.8%). The results showed that the BEMPU TempWatch had significantly fewer misclassifications among neonates who were not treated in an incubator, received only breastmilk, and were not born extremely preterm. Further studies are warranted to evaluate the effectiveness of the BEMPU TempWatch on neonatal health outcomes.Keywords
Funding Information
- Thrasher Research Fund (15194)
This publication has 29 references indexed in Scilit:
- Global, regional, and national estimates of levels of preterm birth in 2014: a systematic review and modelling analysisThe Lancet Global Health, 2019
- Hypothermia detection in low birth weight neonates using a novel bracelet deviceThe Journal of Maternal-Fetal & Neonatal Medicine, 2018
- Point-of-care diagnostics to improve maternal and neonatal health in low-resource settingsLab on a Chip, 2017
- Consensus on kangaroo mother care accelerationThe Lancet, 2013
- Hypothermia in very low birth weight infants: distribution, risk factors and outcomesJournal of Perinatology, 2011
- Receiver Operating Characteristic Curve in Diagnostic Test AssessmentJournal of Thoracic Oncology, 2010
- Neonatal hypothermia in low resource settings: a reviewJournal of Perinatology, 2009
- Neonatal infection and long-term neurodevelopmental outcome in the preterm infantCurrent Opinion in Infectious Diseases, 2006
- Applied Logistic Regression2000
- Statistical Methodology: I. Incorporating the Prevalence of Disease into the Sample Size Calculation for Sensitivity and SpecificityAcademic Emergency Medicine, 1996