Congenital hip dysplasia treated by total hip arthroplasty using cementless tapered stem in patients younger than 50 years old: results after 12-years follow-up
Open Access
- 24 November 2011
- journal article
- research article
- Published by Springer Nature in Journal of Orthopaedics and Traumatology
- Vol. 12 (4) , 213-218
Abstract
Background Congenital hip dysplasia may lead to severe acetabular and femoral abnormalities that can make total hip arthroplasty a challenging procedure. We assessed a series of patients affected by developmental hip dysplasia treated with total hip arthroplasty using cementless tapered stem and here we report the outcomes at long-term follow-up. Materials and methods Twenty-eight patients (24 women and 4 men) aged between 44 and 50 years (mean 47 years) were observed. Clinical evaluation was rated with the Harris Hip Score. Radiographic evaluation consisted in standard anteroposterior and axial view radiographs of the hip. According to Crowe’s classification, 16 hips presented dysplasia grade 1, 14 grade 2, and 4 grade 3. All patients were treated with total hip arthroplasty using a cementless tapered stem (Wagner Cone Prosthesis). Six patients were operated bilaterally, with a totally of 34 hips operated. After surgery, the patients were clinically and radiographically checked at 3, 6, and 12 months and yearly thereafter until an average follow-up of 12 years (range 10–14 years). Results Average Harris Hip Score was 56 ± 9 (range 45–69) preoperatively, 90 ± 9 (range 81–100) 12 months after surgery, and 91 ± 8 (range 83–100) at last follow-up. Radiographic evaluation demonstrated excellent osteointegration of the implants. Signs of bone resorption were present in 6 hips, nevertheless no evidence of loosening was observed and none of the implants has been revised. Conclusions Even in dysplasic femur, the tapered stem allowed adequate stability and orientation of the implant. We consider tapered stem a suitable option for total hip arthroplasty in developmental hip dysplasia, also in case of young patients, thanks to the favourable long-term results.Keywords
This publication has 49 references indexed in Scilit:
- Total Hip Arthroplasty in Developmental Hip Dysplasia Using Cementless Tapered Stem. Results after a Minimum 10-Year Follow-UpHIP International, 2011
- Direct comparison of polyethylene wear in cemented and uncemented acetabular cupsJournal of Orthopaedics and Traumatology, 2010
- No differences in outcomes between cemented and uncemented acetabular components after 12–14 years: results from a randomized controlled trial comparing Duraloc with Charnley cupsJournal of Orthopaedics and Traumatology, 2010
- Femoral bone density changes after total hip arthroplasty with uncemented taper-design stem: a five year follow-up studyInternational Orthopaedics, 2009
- A prospective study of hip revision surgery using the Exeter long-stem prosthesis: function, subsidence, and complications for 57 patientsJournal of Orthopaedics and Traumatology, 2009
- The importance of surgical education in the accuracy of implant placement during hip fracture fixationJournal of Orthopaedics and Traumatology, 2009
- Early catastrophic acetabular failure in Furlong total hip replacementsJournal of Orthopaedics and Traumatology, 2009
- Learning curve in tissue sparing total hip replacement: comparison between different approachesJournal of Orthopaedics and Traumatology, 2009
- Primary Total Hip Arthroplasty in Severe Developmental Dysplasia of the Hip. Ten-Year Results Using a Cementless Modular StemThe Journal of Arthroplasty, 2009
- Excellent results from proximally HA-coated femoral stems with a minimum of 6 years follow-upActa Orthopaedica, 2005