B-type natriuretic peptide and weaning from mechanical ventilation
- 29 August 2006
- journal article
- research article
- Published by Springer Nature in Intensive Care Medicine
- Vol. 32 (10) , 1529-1536
Abstract
Objective Cardiac function and volume status could play a critical role in the setting of weaning failure. B-type natriuretic peptide (BNP) is a powerful marker of cardiac dysfunction. We assessed the value of BNP during the weaning process. Design, setting and patients One hundred and two consecutive patients considered ready to undergo a 1-h weaning trial (T-piece or low-pressure support level) were prospectively included in a medical intensive care unit of a university hospital. Weaning was considered successful if the patient passed the trial and sustained spontaneous breathing for more than 48 h after extubation. Interventions Plasma BNP was measured just before the trial in all patients, and at the end of the trial in the first 60 patients. Results Overall, 42 patients (41.2%) failed the weaning process (37 patients failed the trial and 5 failed extubation). Logistic regression analysis identified high BNP level before the trial and the product of airway pressure and breathing frequency during ventilation as independent risk factors for weaning failure. BNP values were not different at the end of the trial. In nine of the patients in whom the weaning process failed, it succeeded on a later occasion after diuretic therapy. Their BNP level before weaning decreased between the two attempts (517 vs 226 pg/ml, p = 0.01). In survivors, BNP level was significantly correlated to weaning duration (rho = 0.52, p < 0.01). Conclusions Baseline plasma BNP level before the first weaning attempt is higher in patients with subsequent weaning failure and correlates to weaning duration.Keywords
This publication has 40 references indexed in Scilit:
- Impact of age, race, and sex on the ability of B-type natriuretic peptide to aid in the emergency diagnosis of heart failure: results from the Breathing Not Properly (BNP) multinational studyAmerican Heart Journal, 2004
- Utility of B-Natriuretic Peptide in Detecting Diastolic DysfunctionCirculation, 2002
- The physiological and pathophysiological modulation of the endocrine function of the heartCanadian Journal of Physiology and Pharmacology, 2001
- Myocardial ischemia and weaning failure in patients with coronary artery disease: An updateCritical Care Medicine, 1999
- Superiority of Brain Natriuretic Peptide as a Hormonal Marker of Ventricular Systolic and Diastolic Dysfunction and Ventricular HypertrophyHypertension, 1996
- Left ventricular function during weaning of patients with chronic obstructive pulmonary diseaseIntensive Care Medicine, 1994
- Plasma catecholamines and oxygen consumption during weaning from mechanical ventilationIntensive Care Medicine, 1991
- Acute Left Ventricular Dysfunction during Unsuccessful Weaning from Mechanical VentilationAnesthesiology, 1988
- Effect of Intrathoracic Pressure on Left Ventricular PerformanceNew England Journal of Medicine, 1979
- Factors influencing successful discontinuance of mechanical ventilation after open heart surgeryCritical Care Medicine, 1976